A Lightweight Hybrid Representation Learning Framework for Colorectal Lesion Classification in Colonoscopy Images

Accurate colorectal lesion classification is important for computer-aided colonoscopy, yet many existing approaches require computationally intensive architectures. This study proposed and experimentally evaluated LHRF, which integrates BoVW encoding, SAE compression, TE-based metric refinement, optional HC augmentation, and FC-ResNet classification. Two configurations were investigated: LHRF-Core (BoVW → SAE → TE → FC-ResNet) and LHRF-HC, which additionally incorporates clustering-derived features. The experiments included three study-specific binary classification tasks constructed from CVC-ClinicDB, CVC-ColonDB, and a merged Kvasir/Kvasir-SEG collection. The CVC tasks used study-assigned sequence-level pathology categories, with sequence-grouped evaluation for CVC-ClinicDB and source-grouped evaluation for CVC-ColonDB. LHRF-HC achieved the highest accuracy on CVC-ClinicDB (96.24%, AUC 0.9741, MCC 0.9248), whereas LHRF-Core achieved the best results on CVC-ColonDB (95.88%, AUC 0.9698, MCC 0.9176) and Kvasir/Kvasir-SEG (98.74%, AUC 0.9908, MCC 0.9746). Five-fold cross-validation on CVC-ClinicDB yielded an accuracy of 97.43 ± 1.29%. Under matched experimental protocols, LHRF achieved higher classification accuracy than the evaluated lightweight baselines while requiring approximately 0.45–0.51 million trainable parameters. Measured post-decoding CPU throughput ranged from 351.67 to 2353.97 FPS, excluding image decoding and disk input/output. HC improved accuracy on CVC-ClinicDB but slightly reduced it on the other datasets, indicating a dataset-dependent contribution. The study also specified a gradient-based keypoint-attribution procedure, although its empirical faithfulness and clinical interpretability require further evaluation. Overall, the experimental findings highlight the potential of compact hybrid representation learning for colorectal lesion classification. Further evaluation using independently verified pathology annotations, patient-independent partitions, source-matched datasets, and external clinical collections would strengthen the assessment of robustness and clinical generalizability.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2026-11-13
DOI
https://doi.org/10.3390/jimaging12110575
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Lightweight Hybrid Representation Learning Framework for Colorectal Lesion Classification in Colonoscopy Images

Yousef Farhang, Mehmet Akif Çifçi
4 links
Journal of Imaging
Colorectal Cancer Screening and Detection
article

A Lightweight Hybrid Representation Learning Framework for Colorectal Lesion Classification in Colonoscopy Images

Yousef Farhang, Mehmet Akif Çifçi
article en

Abstract

Accurate colorectal lesion classification is important for computer-aided colonoscopy, yet many existing approaches require computationally intensive architectures. This study proposed and experimentally evaluated LHRF, which integrates BoVW encoding, SAE compression, TE-based metric refinement, optional HC augmentation, and FC-ResNet classification. Two configurations were investigated: LHRF-Core (BoVW → SAE → TE → FC-ResNet) and LHRF-HC, which additionally incorporates clustering-derived features. The experiments included three study-specific binary classification tasks constructed from CVC-ClinicDB, CVC-ColonDB, and a merged Kvasir/Kvasir-SEG collection. The CVC tasks used study-assigned sequence-level pathology categories, with sequence-grouped evaluation for CVC-ClinicDB and source-grouped evaluation for CVC-ColonDB. LHRF-HC achieved the highest accuracy on CVC-ClinicDB (96.24%, AUC 0.9741, MCC 0.9248), whereas LHRF-Core achieved the best results on CVC-ColonDB (95.88%, AUC 0.9698, MCC 0.9176) and Kvasir/Kvasir-SEG (98.74%, AUC 0.9908, MCC 0.9746). Five-fold cross-validation on CVC-ClinicDB yielded an accuracy of 97.43 ± 1.29%. Under matched experimental protocols, LHRF achieved higher classification accuracy than the evaluated lightweight baselines while requiring approximately 0.45–0.51 million trainable parameters. Measured post-decoding CPU throughput ranged from 351.67 to 2353.97 FPS, excluding image decoding and disk input/output. HC improved accuracy on CVC-ClinicDB but slightly reduced it on the other datasets, indicating a dataset-dependent contribution. The study also specified a gradient-based keypoint-attribution procedure, although its empirical faithfulness and clinical interpretability require further evaluation. Overall, the experimental findings highlight the potential of compact hybrid representation learning for colorectal lesion classification. Further evaluation using independently verified pathology annotations, patient-independent partitions, source-matched datasets, and external clinical collections would strengthen the assessment of robustness and clinical generalizability.

Journal of ImagingVol. 12(11)
Duy Tan University (VN), Bandırma Onyedi Eylül University (TR), İstanbul Esenyurt Üniversitesi (TR)
Good health and well-being
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon