The single-photon microwave loss of a moiré superconducting element: why the published geometry cannot measure it, and a two-device experiment that can

Moiré superconductors have entered superconducting circuits as inductors, and everyone measures the wrong thing: how much inductance, not how much energy is lost, and never at the single-photon level where circuits operate. The published resonator measurements of two-dimensional superconductors used as inductors were made in a geometry that cannot measure the sample's own loss. This is not an error of execution but a consequence of the geometry: the approximation that extracts the kinetic inductance cleanly is the same approximation that blinds the loss measurement, because the sample's dissipation enters 1/Q_i multiplied by its participation p. On published numbers, and on the reading that the fitted Q_i and the 1% shift belong to the same superconducting device, everything that can be said about the quality factor of a magic-angle element is Q ≥ 21. The obstruction is removed by a mask line: shortening the line until the sample is the resonator drives p from 0.02 to 0.99998. But then the contacts become the experiment, Q_contact = Z/R_c, and the length-ladder regression meant to separate contact from intrinsic loss is degenerate once the gate capacitance a moiré device cannot do without is budgeted; I publish this here about my own design. What replaces it is a differential measurement: one chip, one gate, one cooldown, two lumped resonators matched in layout, one moiré and one base metal, and their difference. I give the element, four controls, pre-registered decision rules, four outcome bands, and the asymmetry that limits how far the number generalizes. I have not performed the measurement; the paper says why.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24204123
Primary Topic
Physics of Superconductivity and Magnetism
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

The single-photon microwave loss of a moiré superconducting element: why the published geometry cannot measure it, and a two-device experiment that can

Faruk Sami Bilgin
1 links
Zenodo (CERN European Organization for Nuclear Research)
Physics of Superconductivity and Magnetism
preprint

The single-photon microwave loss of a moiré superconducting element: why the published geometry cannot measure it, and a two-device experiment that can

Faruk Sami Bilgin
preprint en

Abstract

Moiré superconductors have entered superconducting circuits as inductors, and everyone measures the wrong thing: how much inductance, not how much energy is lost, and never at the single-photon level where circuits operate. The published resonator measurements of two-dimensional superconductors used as inductors were made in a geometry that cannot measure the sample's own loss. This is not an error of execution but a consequence of the geometry: the approximation that extracts the kinetic inductance cleanly is the same approximation that blinds the loss measurement, because the sample's dissipation enters 1/Q_i multiplied by its participation p. On published numbers, and on the reading that the fitted Q_i and the 1% shift belong to the same superconducting device, everything that can be said about the quality factor of a magic-angle element is Q ≥ 21. The obstruction is removed by a mask line: shortening the line until the sample is the resonator drives p from 0.02 to 0.99998. But then the contacts become the experiment, Q_contact = Z/R_c, and the length-ladder regression meant to separate contact from intrinsic loss is degenerate once the gate capacitance a moiré device cannot do without is budgeted; I publish this here about my own design. What replaces it is a differential measurement: one chip, one gate, one cooldown, two lumped resonators matched in layout, one moiré and one base metal, and their difference. I give the element, four controls, pre-registered decision rules, four outcome bands, and the asymmetry that limits how far the number generalizes. I have not performed the measurement; the paper says why.

Zenodo (CERN European Organization for Nuclear Research)
Kocaeli Üniversitesi (TR)
Physics of Superconductivity and Magnetism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon