A wearable health monitoring device addressing temporal signal distortion caused by sample drift
Maintaining temporal alignment of recorded data can be challenging in modern wearable devices which face intrinsic challenges due to constrained processing resources, SD write processes and Bluetooth connections. Missed sample acquisition can lead to non-linear or sporadic timescale distortion, hampering efforts to align timestamps between datasets. Rather than proposing new signal–processing theory, we demonstrate the first real–time embedded implementation that actively detects and corrects sample drift at the point of acquisition in a multi–sensor, SD–recording, Bluetooth–connected wearable system. This paper presents a real-time, embedded solution to sample drift, implemented on an ESP32-based wearable device for continuous monitoring of vital signs, including heart rate, respiration, temperature and accelerometer data. The core contribution is a firmware architecture that exploits the ESP32′s dual-core design: one core is dedicated to uninterrupted data acquisition and signal processing, while the second core manages data buffering, paced SD card writing and Bluetooth communications. On-board signal processing calculations are performed intermittently, and this approach mitigates some of the sample drift. Crucially, delayed sampling caused by Bluetooth interruptions and hardware limitations are further rectified by taking a dual sample shortly after missed samples to realign with a timing signal. This multi-modal approach effectively mitigates sample drift at the point of data collection which reduces the need for post-recording alignment due to missed samples within database recordings for wearable biomedical devices.
Authors
- Ram Kuber Singh (ORCID: https://orcid.org/0000-0003-1887-5473)
- Jessica Centracchio (ORCID: https://orcid.org/0000-0003-3422-8727)
- Upul Gunawardana (ORCID: https://orcid.org/0000-0003-0932-5306)
- Salvatore J. Parlato (ORCID: https://orcid.org/0009-0000-9314-5126)
- Gaetano Dario Gargiulo (ORCID: https://orcid.org/0000-0002-2616-2804)
- Paul P. Breen (ORCID: https://orcid.org/0000-0002-8860-2086)
- Ben Brandwood (ORCID: https://orcid.org/0009-0008-8404-097X)
Institutions
- Translational Research Institute (AU)
- Westmead Institute (AU)
- Ingham Institute (AU)
- Westmead Institute for Medical Research (AU)
- Western Sydney University (AU)
- University of Naples Federico II (IT)
Publication Details
- Journal
- Biomedical Signal Processing and Control
- Published
- 2026-11-13
- DOI
- https://doi.org/10.1016/j.bspc.2026.111806
- Primary Topic
- Non-Invasive Vital Sign Monitoring
- Type
- article
- Field-Weighted Citation Impact
- 0.00