A wearable health monitoring device addressing temporal signal distortion caused by sample drift

Maintaining temporal alignment of recorded data can be challenging in modern wearable devices which face intrinsic challenges due to constrained processing resources, SD write processes and Bluetooth connections. Missed sample acquisition can lead to non-linear or sporadic timescale distortion, hampering efforts to align timestamps between datasets. Rather than proposing new signal–processing theory, we demonstrate the first real–time embedded implementation that actively detects and corrects sample drift at the point of acquisition in a multi–sensor, SD–recording, Bluetooth–connected wearable system. This paper presents a real-time, embedded solution to sample drift, implemented on an ESP32-based wearable device for continuous monitoring of vital signs, including heart rate, respiration, temperature and accelerometer data. The core contribution is a firmware architecture that exploits the ESP32′s dual-core design: one core is dedicated to uninterrupted data acquisition and signal processing, while the second core manages data buffering, paced SD card writing and Bluetooth communications. On-board signal processing calculations are performed intermittently, and this approach mitigates some of the sample drift. Crucially, delayed sampling caused by Bluetooth interruptions and hardware limitations are further rectified by taking a dual sample shortly after missed samples to realign with a timing signal. This multi-modal approach effectively mitigates sample drift at the point of data collection which reduces the need for post-recording alignment due to missed samples within database recordings for wearable biomedical devices.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-11-13
DOI
https://doi.org/10.1016/j.bspc.2026.111806
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A wearable health monitoring device addressing temporal signal distortion caused by sample drift

Ram Kuber Singh, Jessica Centracchio, Upul Gunawardana, Salvatore J. Parlato et al.
Biomedical Signal Processing and Control
Non-Invasive Vital Sign Monitoring
article

A wearable health monitoring device addressing temporal signal distortion caused by sample drift

Ram Kuber Singh, Jessica Centracchio, Upul Gunawardana, Salvatore J. Parlato, Gaetano Dario Gargiulo, Paul P. Breen, Ben Brandwood
article en

Abstract

Maintaining temporal alignment of recorded data can be challenging in modern wearable devices which face intrinsic challenges due to constrained processing resources, SD write processes and Bluetooth connections. Missed sample acquisition can lead to non-linear or sporadic timescale distortion, hampering efforts to align timestamps between datasets. Rather than proposing new signal–processing theory, we demonstrate the first real–time embedded implementation that actively detects and corrects sample drift at the point of acquisition in a multi–sensor, SD–recording, Bluetooth–connected wearable system. This paper presents a real-time, embedded solution to sample drift, implemented on an ESP32-based wearable device for continuous monitoring of vital signs, including heart rate, respiration, temperature and accelerometer data. The core contribution is a firmware architecture that exploits the ESP32′s dual-core design: one core is dedicated to uninterrupted data acquisition and signal processing, while the second core manages data buffering, paced SD card writing and Bluetooth communications. On-board signal processing calculations are performed intermittently, and this approach mitigates some of the sample drift. Crucially, delayed sampling caused by Bluetooth interruptions and hardware limitations are further rectified by taking a dual sample shortly after missed samples to realign with a timing signal. This multi-modal approach effectively mitigates sample drift at the point of data collection which reduces the need for post-recording alignment due to missed samples within database recordings for wearable biomedical devices.

Biomedical Signal Processing and ControlVol. 131
Translational Research Institute (AU), Westmead Institute (AU), Ingham Institute (AU), Westmead Institute for Medical Research (AU), Western Sydney University (AU), University of Naples Federico II (IT)
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon