Two-Dimensional Correlation Mass Spectrometry for Precursor/Fragment Ion Identification of Composite and Unresolved Spectral Peaks

Abstract Two-dimensional correlation mass spectrometry (2D-CMS) is a cross-correlation-based technique that can be used to identify mass-spectral signals that arise from a common molecular origin. In this study, 2D-CMS is explored for mixtures of the blood-pressure medications atenolol and metoprolol with the specific aims of precursor/fragment-ion identification and deconvolution of unresolved spectral peaks. Atenolol and metoprolol are structurally similar and produce several identical or isobaric fragment ions. In addition, the first isotopic peak of the atenolol ion (i.e., [MH++1]) at m/z 268.1737 and the protonated metoprolol ion at m/z 268.1834 produce an isobaric overlap for the mass-spectral resolving power used in this study (m/Δm = 17,500 at m/z 200). These phenomena result in numerous peaks that originate from both analytes, complicating the interpretation of mass-spectral results for precursor/fragment identification and assignment of overlapped peaks. Semiquantitative information extracted from 2D-CMS results enabled the determination of the relative contribution of each analyte to the total signal of their shared fragments. In addition, narrow m/z regions within unresolved mass-spectral peaks could be attributed to their specific molecular origin. For a series of solutions with varying proportions of each analyte, metrics derived from 2D-CMS were found to scale with the relative concentration of each analyte. Calibration results obtained from 2D-CMS were comparable to those obtained from traditional peak-fitting methods but provided additional information that enabled peak identification. These results show the utility of 2D-CMS for deconvolution of mass spectra acquired without separation or isolation of analytes or at low resolving powers.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-11-13
DOI
https://doi.org/10.1021/jasms.6c00308
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Two-Dimensional Correlation Mass Spectrometry for Precursor/Fragment Ion Identification of Composite and Unresolved Spectral Peaks

Jacob T. Shelley, Elly A. Breves, Garon H. Lowke
1 links
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Two-Dimensional Correlation Mass Spectrometry for Precursor/Fragment Ion Identification of Composite and Unresolved Spectral Peaks

Jacob T. Shelley, Elly A. Breves, Garon H. Lowke
article en

Abstract

Abstract Two-dimensional correlation mass spectrometry (2D-CMS) is a cross-correlation-based technique that can be used to identify mass-spectral signals that arise from a common molecular origin. In this study, 2D-CMS is explored for mixtures of the blood-pressure medications atenolol and metoprolol with the specific aims of precursor/fragment-ion identification and deconvolution of unresolved spectral peaks. Atenolol and metoprolol are structurally similar and produce several identical or isobaric fragment ions. In addition, the first isotopic peak of the atenolol ion (i.e., [MH++1]) at m/z 268.1737 and the protonated metoprolol ion at m/z 268.1834 produce an isobaric overlap for the mass-spectral resolving power used in this study (m/Δm = 17,500 at m/z 200). These phenomena result in numerous peaks that originate from both analytes, complicating the interpretation of mass-spectral results for precursor/fragment identification and assignment of overlapped peaks. Semiquantitative information extracted from 2D-CMS results enabled the determination of the relative contribution of each analyte to the total signal of their shared fragments. In addition, narrow m/z regions within unresolved mass-spectral peaks could be attributed to their specific molecular origin. For a series of solutions with varying proportions of each analyte, metrics derived from 2D-CMS were found to scale with the relative concentration of each analyte. Calibration results obtained from 2D-CMS were comparable to those obtained from traditional peak-fitting methods but provided additional information that enabled peak identification. These results show the utility of 2D-CMS for deconvolution of mass spectra acquired without separation or isolation of analytes or at low resolving powers.

Journal of the American Society for Mass Spectrometry
Wingate University (US), Rensselaer Polytechnic Institute (US)
National Aeronautics and Space Administration
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon