Automated Ventilation in Comparison With Conventional Mechanical Ventilation

Background: INTELLiVENT-ASV is a closed-loop automated mechanical ventilation mode, adjusting parameters based on gas exchange and lung mechanics. This study compared conventional ventilation with automated ventilation to compare safety and efficacy. Methods: Prospective, multi-center, international, 1:1 randomized controlled study conducted between January 2021 and June 2022 at 5 hospitals in Europe and the USA enrolling adult mechanically ventilated subjects, which was stopped early because of the discontinuation of the G5/S1 ventilator platform. Subjects received automation or conventional mechanical ventilation through extubation. Primary end point was a composite “safety” and “efficacy” measure based upon gas exchange and mechanics. Secondary end points included outcomes, F IO 2 use, S pO 2 , and respiratory mechanics. Results: 62 subjects were enrolled and 60 analyzed with even distribution between groups, similar baseline characteristics, physiologic parameters, and ventilator settings. The percentage of breaths within the optimal “efficacy” windows (28% [19–37] vs 29% [8–39], P = .60) and within the optimal “safety” thresholds (16% [3–39] vs 13% [8–19], P = .66) was similar between groups. Subjects in the automated mode arm had significantly lower set F iO 2 and higher percentage of time spent in the “optimal” S pO 2 window (84 [70–97] vs 70 [51–87], P = .048), with qualitatively lower percentages spent in the “unacceptably low” and “acceptably higher” windows. Outcomes were similar between groups. Conclusions: Automation performed similarly to conventional nonautomated ventilation at multiple academic tertiary care centers, with similar respiratory mechanics and subject outcomes. Use of the automated mode resulted in lower F iO 2 , but a higher percentage of time spent in the “optimal” oxygenation window. Owing to the small number of subjects from the early stopping of the trial, these findings are exploratory and need validation in a larger number of subjects.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2026-11-13
DOI
https://doi.org/10.1177/19433654261497917
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Automated Ventilation in Comparison With Conventional Mechanical Ventilation

Matija Jurjević, Philipp K. Buehler, Philip Fortuna, Emmanuel Cantais et al.
1 links
Respiratory Care
Respiratory Support and Mechanisms
article

Automated Ventilation in Comparison With Conventional Mechanical Ventilation

Matija Jurjević, Philipp K. Buehler, Philip Fortuna, Emmanuel Cantais, Elias Baedorf Kassis, Reto Andreas Schuepbach, Jean-Michel Arnal, Marco Maggiorini, Daniel S. Talmor, Dominik Novotni, Jan Zimmermann, Valerie Goodspeed
article en

Abstract

Background: INTELLiVENT-ASV is a closed-loop automated mechanical ventilation mode, adjusting parameters based on gas exchange and lung mechanics. This study compared conventional ventilation with automated ventilation to compare safety and efficacy. Methods: Prospective, multi-center, international, 1:1 randomized controlled study conducted between January 2021 and June 2022 at 5 hospitals in Europe and the USA enrolling adult mechanically ventilated subjects, which was stopped early because of the discontinuation of the G5/S1 ventilator platform. Subjects received automation or conventional mechanical ventilation through extubation. Primary end point was a composite “safety” and “efficacy” measure based upon gas exchange and mechanics. Secondary end points included outcomes, F IO 2 use, S pO 2 , and respiratory mechanics. Results: 62 subjects were enrolled and 60 analyzed with even distribution between groups, similar baseline characteristics, physiologic parameters, and ventilator settings. The percentage of breaths within the optimal “efficacy” windows (28% [19–37] vs 29% [8–39], P = .60) and within the optimal “safety” thresholds (16% [3–39] vs 13% [8–19], P = .66) was similar between groups. Subjects in the automated mode arm had significantly lower set F iO 2 and higher percentage of time spent in the “optimal” S pO 2 window (84 [70–97] vs 70 [51–87], P = .048), with qualitatively lower percentages spent in the “unacceptably low” and “acceptably higher” windows. Outcomes were similar between groups. Conclusions: Automation performed similarly to conventional nonautomated ventilation at multiple academic tertiary care centers, with similar respiratory mechanics and subject outcomes. Use of the automated mode resulted in lower F iO 2 , but a higher percentage of time spent in the “optimal” oxygenation window. Owing to the small number of subjects from the early stopping of the trial, these findings are exploratory and need validation in a larger number of subjects.

Respiratory Care
Beth Israel Deaconess Medical Center (US), University of Zurich (CH), Unidade Local de Saúde de São José (PT), Kantonsspital Winterthur (CH), University Hospital of Zurich (CH), Hamilton Medical (Switzerland) (CH), Hôpital Saint Joseph (FR), University of Slavonski Brod (HR), General Hospital Dr. Josip Benčević Slavonski Brod (HR)
Good health and well-being
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon