Barrier Lyapunov Function-Based Prescribed Performance Control for Multi-Input, Multi-Output Nonlinear System: Application to Dual-Phase Gas–Liquid Transmembrane Pressure System

Pressure regulation in dual-phase gas–liquid membrane systems remains difficult, given that the gas and liquid phases exhibit significantly different transient behaviors and are connected by the permeability and flexibility of the membranes. Therefore, this research presents a barrier Lyapunov function-based prescribed performance control (BLF-PPC) approach for a nonlinear multi-input, multi-output transmembrane pressure control system. Specifically, a nonlinear state-space model has been proposed by considering gas compressibility, liquid hydraulic effects, nonlinearities in valves, membrane permeation effects, and deformation of the polytetrafluoroethylene (PTFE) tube. The prescribed performance functions (PPFs) bound the tracking errors, while the logarithmic barrier Lyapunov function ensures that the difference in pressure between channels is within the predefined safety boundary. Lyapunov stability analysis rigorously proves uniform ultimate boundedness (UUB) of all closed-loop signals, confinement of tracking errors within predefined performance envelopes, and satisfaction of constraints. Simulation results at 1, 3, and 5 bar confirm that overshooting is avoided in the tracking process, the settling time is approximately 4 s, and steady-state errors are below 1000 Pa. The upper bound for differential pressure is set at 0.0027 bar, which accounts for 5.6% of the controller design barrier bound of 0.05 bar. When a serious 95% water valve blockage fault occurs, the system recovers in about 2.5 s, keeping the differential pressure below 0.03 bar. As a result, it demonstrates the superior constraint-handling capability of the proposed controller.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-13
DOI
https://doi.org/10.3390/app162211268
Primary Topic
Adaptive Control of Nonlinear Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Barrier Lyapunov Function-Based Prescribed Performance Control for Multi-Input, Multi-Output Nonlinear System: Application to Dual-Phase Gas–Liquid Transmembrane Pressure System

Thandapani Marimuthu, Hee‐Tae Jung, Cong Toai Truong, Tan Tien Nguyen et al.
1 links
Applied Sciences
Adaptive Control of Nonlinear Systems
article

Barrier Lyapunov Function-Based Prescribed Performance Control for Multi-Input, Multi-Output Nonlinear System: Application to Dual-Phase Gas–Liquid Transmembrane Pressure System

Thandapani Marimuthu, Hee‐Tae Jung, Cong Toai Truong, Tan Tien Nguyen, Van Tu Duong, Trung Dat Phan, Jinpil Ha, Hai Dang Ho, Huu Nhan Nguyen, Huy Hung Nguyen
article en

Abstract

Pressure regulation in dual-phase gas–liquid membrane systems remains difficult, given that the gas and liquid phases exhibit significantly different transient behaviors and are connected by the permeability and flexibility of the membranes. Therefore, this research presents a barrier Lyapunov function-based prescribed performance control (BLF-PPC) approach for a nonlinear multi-input, multi-output transmembrane pressure control system. Specifically, a nonlinear state-space model has been proposed by considering gas compressibility, liquid hydraulic effects, nonlinearities in valves, membrane permeation effects, and deformation of the polytetrafluoroethylene (PTFE) tube. The prescribed performance functions (PPFs) bound the tracking errors, while the logarithmic barrier Lyapunov function ensures that the difference in pressure between channels is within the predefined safety boundary. Lyapunov stability analysis rigorously proves uniform ultimate boundedness (UUB) of all closed-loop signals, confinement of tracking errors within predefined performance envelopes, and satisfaction of constraints. Simulation results at 1, 3, and 5 bar confirm that overshooting is avoided in the tracking process, the settling time is approximately 4 s, and steady-state errors are below 1000 Pa. The upper bound for differential pressure is set at 0.0027 bar, which accounts for 5.6% of the controller design barrier bound of 0.05 bar. When a serious 95% water valve blockage fault occurs, the system recovers in about 2.5 s, keeping the differential pressure below 0.03 bar. As a result, it demonstrates the superior constraint-handling capability of the proposed controller.

Applied SciencesVol. 16(22)
Vietnam National University Ho Chi Minh City (VN), Korea Advanced Institute of Science and Technology (KR), Ho Chi Minh City University of Technology and Engineering (VN), Ho Chi Minh City University of Technology (VN)
Viet Nam National University Ho Chi Minh City
Adaptive Control of Nonlinear Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon