Detector-Area Requirements for Imaging the Summit Conduit of Mount Vesuvius by Cosmic-Ray Muons

This paper computes the muon attenuation, exposure and resolution budget for imaging Mount Vesuvius with cosmic-ray muons. Sight lines through 700 metres of volcanic rock at a density of 2.6 grams per cubic centimetre present an opacity of 1.82e+05 grams per square centimetre (1820 metres of water equivalent), which sets a minimum muon energy of 509 GeV and a transmitted vertical intensity of 0.002906 per square metre per second per steradian. For a detector of 1 square metres with the stated acceptance and efficiency, divided among 400 image elements, the stated feature produces a flux contrast of 0.8556 and reaches five standard deviations in 194.3 days of counting, while the target precision of 0.05 per image element requires 2276 days. A deployment of 365 days delivers a per-element precision of 0.1249, corresponding to a thickness sensitivity of 87.4 metres. The combined angular resolution is 4.092 milliradians, of which tracking contributes 2.828 milliradians and multiple scattering at the threshold momentum 2.957 milliradians. The budget is compared with published muography of the same class of target, for which muography campaigns at Vesuvius with the MURAVES detector have reported density structure in the upper cone after exposures of many months with detectors of order one square metre. Every number is computed by the accompanying script from the stated inputs. Computed, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24206888
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Detector-Area Requirements for Imaging the Summit Conduit of Mount Vesuvius by Cosmic-Ray Muons

William Alexander Aldred
18 links
Zenodo (CERN European Organization for Nuclear Research)
Particle Detector Development and Performance
article

Detector-Area Requirements for Imaging the Summit Conduit of Mount Vesuvius by Cosmic-Ray Muons

William Alexander Aldred
article en

Abstract

This paper computes the muon attenuation, exposure and resolution budget for imaging Mount Vesuvius with cosmic-ray muons. Sight lines through 700 metres of volcanic rock at a density of 2.6 grams per cubic centimetre present an opacity of 1.82e+05 grams per square centimetre (1820 metres of water equivalent), which sets a minimum muon energy of 509 GeV and a transmitted vertical intensity of 0.002906 per square metre per second per steradian. For a detector of 1 square metres with the stated acceptance and efficiency, divided among 400 image elements, the stated feature produces a flux contrast of 0.8556 and reaches five standard deviations in 194.3 days of counting, while the target precision of 0.05 per image element requires 2276 days. A deployment of 365 days delivers a per-element precision of 0.1249, corresponding to a thickness sensitivity of 87.4 metres. The combined angular resolution is 4.092 milliradians, of which tracking contributes 2.828 milliradians and multiple scattering at the threshold momentum 2.957 milliradians. The budget is compared with published muography of the same class of target, for which muography campaigns at Vesuvius with the MURAVES detector have reported density structure in the upper cone after exposures of many months with detectors of order one square metre. Every number is computed by the accompanying script from the stated inputs. Computed, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon