Mechanical behaviour of the intact brain-skull interface under tension, compression and shear

The brain-skull interface governs the boundary/contact conditions of the brain in computational head models, yet its mechanical behaviour remains poorly characterised experimentally. We characterised the brain-skull interface by testing brain-skull complex samples (skull bone, meninges and brain tissue in their native arrangement) excised from 19 sheep cadaver heads under uniaxial tension and compression at strain rates of 0.002, 0.02 and 0.2 s$^{-1}$ and simple shear at 0.02 s$^{-1}$. Histology confirmed that the meningeal layers remained intact and attached to the brain and skull after excision. We acquired magnetic resonance images of every sample, reconstructed their geometry and developed a sample-specific finite element model of each experiment. We represented the brain tissue using a second-order Ogden hyperelastic model and the brain-skull interface using a cohesive zone model. Using inverse finite element analysis, we first calibrated the brain tissue parameters for each subject. Keeping these parameters fixed, we then identified the interface parameters from the corresponding brain-skull complex specimen. The brain tissue shear modulus increased with strain rate from 0.94 $\pm$ 0.16 kPa at 0.002 s$^{-1}$ to 1.60 $\pm$ 0.30 kPa at 0.2 s$^{-1}$. In contrast, the interface properties (maximum normal traction 2.35 $\pm$ 0.81 kPa, maximum tangential traction 4.14 $\pm$ 0.97 kPa, and fracture energy 0.35 $\pm$ 0.14 N m$^{-1}$) showed no significant dependence on strain rate or loading mode. In all samples, failure occurred within the subarachnoid space. Neither a rigid brain-skull connection nor frictionless sliding contact with separation reproduced the measured mechanical response or failure mode of the brain-skull interface. Our experimentally derived cohesive zone model provides a realistic representation of the brain-skull interface for computational head models.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-12
DOI
https://doi.org/10.48550/arxiv.2611.16197
Primary Topic
Elasticity and Material Modeling
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Mechanical behaviour of the intact brain-skull interface under tension, compression and shear

Adam Wittek, Sajjad Arzemanzadeh, Karol Miller, Ron Kikinis
arXiv (Cornell University)
Elasticity and Material Modeling
preprint

Mechanical behaviour of the intact brain-skull interface under tension, compression and shear

Adam Wittek, Sajjad Arzemanzadeh, Karol Miller, Ron Kikinis
preprint en

Abstract

The brain-skull interface governs the boundary/contact conditions of the brain in computational head models, yet its mechanical behaviour remains poorly characterised experimentally. We characterised the brain-skull interface by testing brain-skull complex samples (skull bone, meninges and brain tissue in their native arrangement) excised from 19 sheep cadaver heads under uniaxial tension and compression at strain rates of 0.002, 0.02 and 0.2 s$^{-1}$ and simple shear at 0.02 s$^{-1}$. Histology confirmed that the meningeal layers remained intact and attached to the brain and skull after excision. We acquired magnetic resonance images of every sample, reconstructed their geometry and developed a sample-specific finite element model of each experiment. We represented the brain tissue using a second-order Ogden hyperelastic model and the brain-skull interface using a cohesive zone model. Using inverse finite element analysis, we first calibrated the brain tissue parameters for each subject. Keeping these parameters fixed, we then identified the interface parameters from the corresponding brain-skull complex specimen. The brain tissue shear modulus increased with strain rate from 0.94 $\pm$ 0.16 kPa at 0.002 s$^{-1}$ to 1.60 $\pm$ 0.30 kPa at 0.2 s$^{-1}$. In contrast, the interface properties (maximum normal traction 2.35 $\pm$ 0.81 kPa, maximum tangential traction 4.14 $\pm$ 0.97 kPa, and fracture energy 0.35 $\pm$ 0.14 N m$^{-1}$) showed no significant dependence on strain rate or loading mode. In all samples, failure occurred within the subarachnoid space. Neither a rigid brain-skull connection nor frictionless sliding contact with separation reproduced the measured mechanical response or failure mode of the brain-skull interface. Our experimentally derived cohesive zone model provides a realistic representation of the brain-skull interface for computational head models.

arXiv (Cornell University)
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon