A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method

Prestressing may delay tensile-damage initiation in glass-fibre reinforced polymer (GFRP)-reinforced concrete beams, but the relationship between transferred reinforcement stress and the subsequent tensile-damage development requires consistent numerical evaluation. This study develops and calibrates a three-dimensional finite-element model based on the concrete damaged plasticity (CDP) framework against published four-point bending experimental data. For the Goldston benchmark beam, the FE-predicted first-cracking load, peak load and deflection at peak load differ from the corresponding experimental values by 4.3%, 10.2% and 6.5%, respectively. Five parametric beam configurations are investigated: non-prestressed steel-reinforced B40, non-prestressed GFRP-reinforced C40, and prestressed GFRP-reinforced beams P4, P8 and P12. An equivalent cooling method is employed to introduce prestress, and the mean post-transfer GFRP axial stress is extracted from the numerical results. Using a consistent numerical damage-onset criterion of DAMAGET ≥ 0.001 within a predefined bottom midspan region, the numerical tensile-damage onset loads are 20.54, 16.39, 26.51, 35.70 and 45.51 kN for B40, C40, P4, P8 and P12, respectively. The mean post-transfer GFRP axial stresses in P4, P8 and P12 are 57.27, 114.54 and 171.79 MPa, respectively. Compared with the non-prestressed GFRP reference C40, the corresponding numerical tensile-damage onset loads increase by 61.7%, 117.8% and 177.7%, respectively. At a common loading-point displacement of 5 mm, the element-volume fraction of the predefined midspan region with DAMAGET > 0.05 decreases from 28.39% for C40 to 16.54% for P12, although the local maximum damage does not decrease monotonically. The results demonstrate that prestress can delay numerical tensile-damage initiation and reduce the spatial extent of appreciable midspan tensile damage under the adopted embedded-reinforcement model, without directly predicting physical crack width.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-13
DOI
https://doi.org/10.3390/buildings16224527
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method

Saiqing Peng, Ruoqiang Feng, Shijun Huang, Yihang Jia et al.
Buildings
Structural Behavior of Reinforced Concrete
article

A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method

Saiqing Peng, Ruoqiang Feng, Shijun Huang, Yihang Jia, Dengfeng Zhou, Zijian Song
article en

Abstract

Prestressing may delay tensile-damage initiation in glass-fibre reinforced polymer (GFRP)-reinforced concrete beams, but the relationship between transferred reinforcement stress and the subsequent tensile-damage development requires consistent numerical evaluation. This study develops and calibrates a three-dimensional finite-element model based on the concrete damaged plasticity (CDP) framework against published four-point bending experimental data. For the Goldston benchmark beam, the FE-predicted first-cracking load, peak load and deflection at peak load differ from the corresponding experimental values by 4.3%, 10.2% and 6.5%, respectively. Five parametric beam configurations are investigated: non-prestressed steel-reinforced B40, non-prestressed GFRP-reinforced C40, and prestressed GFRP-reinforced beams P4, P8 and P12. An equivalent cooling method is employed to introduce prestress, and the mean post-transfer GFRP axial stress is extracted from the numerical results. Using a consistent numerical damage-onset criterion of DAMAGET ≥ 0.001 within a predefined bottom midspan region, the numerical tensile-damage onset loads are 20.54, 16.39, 26.51, 35.70 and 45.51 kN for B40, C40, P4, P8 and P12, respectively. The mean post-transfer GFRP axial stresses in P4, P8 and P12 are 57.27, 114.54 and 171.79 MPa, respectively. Compared with the non-prestressed GFRP reference C40, the corresponding numerical tensile-damage onset loads increase by 61.7%, 117.8% and 177.7%, respectively. At a common loading-point displacement of 5 mm, the element-volume fraction of the predefined midspan region with DAMAGET > 0.05 decreases from 28.39% for C40 to 16.54% for P12, although the local maximum damage does not decrease monotonically. The results demonstrate that prestress can delay numerical tensile-damage initiation and reduce the spatial extent of appreciable midspan tensile damage under the adopted embedded-reinforcement model, without directly predicting physical crack width.

BuildingsVol. 16(22)
State Grid Jiangsu Electric Power (China) (CN), Southeast University (CN)
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon