Γ-Cantilever Mechanism-Informed BP Neural Network Compensation for Gap Measurement of an Integrated Knee Distractor in Total Knee Arthroplasty
In total knee arthroplasty (TKA), intraoperative soft-tissue balance and joint gap accuracy directly affect postoperative joint stability, functional recovery and long-term implant survivorship, but current clinical practice still lacks stable, quantitative measurement tools with sufficient precision. This study developed an integrated knee distractor with integrated force feedback and gap detection; the hardware design reserves two independent actuation channels, whereas all experiments reported in this study were conducted in single-channel mode. A mechanism-informed nonlinear error compensation method was proposed to reduce load-dependent gap-measurement error. First, the load-bearing structure was abstracted as a Γ-shaped cantilever beam model under small-deformation and linear-elastic assumptions, and mechanical analysis was conducted to clarify the formation mechanism of gap measurement error induced by load-induced structural deformation and assembly inaccuracies. Guided by this mechanistic analysis, a dual-input BP neural network was constructed with displacement-sensor output and measured force as inputs and the actual distraction gap as output; the mechanical model informed the selection of these two inputs (mechanism-informed input selection) rather than imposing deformation equations as training constraints. The model was trained and evaluated using 200 averaged calibration samples, constructed from a structured grid of 40 displacement settings (0.5–20 mm at 0.5 mm intervals) crossed with five nominal force levels (20, 40, 60, 80, and 100 N), split at the averaged-sample level into 140 training, 20 validation, and 40 test samples. On the independent test set, the proposed method achieved a root mean square error (RMSE) of 0.1123 mm, a mean absolute error (MAE) of 0.0893 mm, and a maximum absolute error (MaxAE) of 0.3189 mm, with all 40 test samples having absolute errors below the predefined engineering accuracy target of ±0.5 mm under the specified bench-top conditions. This study provides a promising engineering approach for reducing load-dependent gap-measurement error under controlled bench-top conditions; validation on anatomically and biomechanically realistic systems is required before any claim of intraoperative suitability.
Authors
- Enkui Zhang (ORCID: https://orcid.org/0009-0008-9039-4440)
- He Xu (ORCID: https://orcid.org/0000-0003-3333-2880)
- Tailin Han (ORCID: https://orcid.org/0000-0003-2193-0242)
- Mingchi Ju (ORCID: https://orcid.org/0000-0002-7744-350X)
- Xuan Liu (ORCID: https://orcid.org/0000-0002-9331-6543)
- Jun Hu
- Guanyu Chen
Institutions
- Changchun University of Science and Technology (CN)
Publication Details
- Journal
- Sensors
- Published
- 2026-11-13
- DOI
- https://doi.org/10.3390/s26227169
- Primary Topic
- Total Knee Arthroplasty Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00