Clinical investigation of the transfer accuracy of semi-digital and fully digital indirect bonding trays

Abstract Background This study aimed to compare the accuracy of semi-digital and fully digital indirect bonding transfer trays in transferring virtually planned bracket positions to the patient’s mouth and to evaluate their suitability for clinical use in patients with mild dental crowding. Methods Thirty-two patients with fully erupted permanent teeth and mild dental crowding who applied to the Department of Orthodontics at Selcuk University were included in the study. Participants were randomly divided into two equal groups. One group received indirect bonding using semi-digital transfer trays, while the other group used fully digital trays. After bonding, intraoral scan images were obtained and superimposed using the GOM Inspect software to measure linear and angular deviations between the planned and actual bracket positions. The data were analyzed statistically. Results No statistically significant difference was found between the groups regarding linear deviations, indicating both methods were linearly accurate. However, angular deviations (especially rotation and torque) were significantly lower in the semi-digital group. In both groups, vertical deviations tended to be gingivally oriented. Conclusions Both transfer tray methods demonstrated adequate linear accuracy. Semi-digital trays showed lower angular (torque and rotation) deviation, a difference that persisted after adjustment for within-patient clustering, suggesting a possible advantage that should be confirmed in larger studies. Trial registration ClinicalTrials.gov NCT07318857, retrospectively registered on 6 January 2026 (actual study start date: 15 June 2023; primary completion date: 21 May 2024).

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-13
DOI
https://doi.org/10.1186/s12903-026-10448-6
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical investigation of the transfer accuracy of semi-digital and fully digital indirect bonding trays

Zehra İleri, Ramazan Emre Karakoc
1 links
BMC Oral Health
Orthodontics and Dentofacial Orthopedics
article

Clinical investigation of the transfer accuracy of semi-digital and fully digital indirect bonding trays

Zehra İleri, Ramazan Emre Karakoc
article en

Abstract

Abstract Background This study aimed to compare the accuracy of semi-digital and fully digital indirect bonding transfer trays in transferring virtually planned bracket positions to the patient’s mouth and to evaluate their suitability for clinical use in patients with mild dental crowding. Methods Thirty-two patients with fully erupted permanent teeth and mild dental crowding who applied to the Department of Orthodontics at Selcuk University were included in the study. Participants were randomly divided into two equal groups. One group received indirect bonding using semi-digital transfer trays, while the other group used fully digital trays. After bonding, intraoral scan images were obtained and superimposed using the GOM Inspect software to measure linear and angular deviations between the planned and actual bracket positions. The data were analyzed statistically. Results No statistically significant difference was found between the groups regarding linear deviations, indicating both methods were linearly accurate. However, angular deviations (especially rotation and torque) were significantly lower in the semi-digital group. In both groups, vertical deviations tended to be gingivally oriented. Conclusions Both transfer tray methods demonstrated adequate linear accuracy. Semi-digital trays showed lower angular (torque and rotation) deviation, a difference that persisted after adjustment for within-patient clustering, suggesting a possible advantage that should be confirmed in larger studies. Trial registration ClinicalTrials.gov NCT07318857, retrospectively registered on 6 January 2026 (actual study start date: 15 June 2023; primary completion date: 21 May 2024).

BMC Oral Health
Selçuk University (TR)
Good health and well-being
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon