UPQC Intelligent Adaptive Optimization Model for the Reactive Power Compensation

This paper presents a proposed Intelligent Optimized Second-Order Unified Power Quality Conditioner (IO-SO-UPQC) for reactive power compensation, voltage regulation, and harmonic mitigation in modern distribution networks. The system integrates a hierarchical control structure comprising an inner second-order derivative-based UPQC control layer, a fuzzy adaptive layer for dynamic gain adjustment, and a global optimization layer using Second-Order Sea-Gull Optimization (SO-SGO) for real-time tuning of controller gains. The series and shunt converters work synergistically to compensate voltage sags, swells, and reactive power variations, while the fuzzy logic layer adjusts the proportional, integral, and derivative gains based on instantaneous error and its rate of change. Simulation results under linear, nonlinear, unbalanced, and sudden load variations show that the proposed IO-SO-UPQC reduces reactive power error from 0.45 kVAR to 0.12 kVAR, voltage deviation from 2% to 0.5%, and total harmonic distortion (THD) from 4.5% to 1.8%, while improving settling time from 35 ms to 15 ms. These results demonstrate superior transient response and robust real-time power quality improvement compared to conventional PI-controlled UPQCs.

Authors

Institutions

Publication Details

Journal
The International Journal of Maritime Engineering
Published
2026-11-13
DOI
https://doi.org/10.5750/ijme.v168ia6(s).2031
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

UPQC Intelligent Adaptive Optimization Model for the Reactive Power Compensation

G. Sujatha, S. Venkata Padmavathi
1 links
The International Journal of Maritime Engineering
Power Quality and Harmonics
article

UPQC Intelligent Adaptive Optimization Model for the Reactive Power Compensation

G. Sujatha, S. Venkata Padmavathi
article en

Abstract

This paper presents a proposed Intelligent Optimized Second-Order Unified Power Quality Conditioner (IO-SO-UPQC) for reactive power compensation, voltage regulation, and harmonic mitigation in modern distribution networks. The system integrates a hierarchical control structure comprising an inner second-order derivative-based UPQC control layer, a fuzzy adaptive layer for dynamic gain adjustment, and a global optimization layer using Second-Order Sea-Gull Optimization (SO-SGO) for real-time tuning of controller gains. The series and shunt converters work synergistically to compensate voltage sags, swells, and reactive power variations, while the fuzzy logic layer adjusts the proportional, integral, and derivative gains based on instantaneous error and its rate of change. Simulation results under linear, nonlinear, unbalanced, and sudden load variations show that the proposed IO-SO-UPQC reduces reactive power error from 0.45 kVAR to 0.12 kVAR, voltage deviation from 2% to 0.5%, and total harmonic distortion (THD) from 4.5% to 1.8%, while improving settling time from 35 ms to 15 ms. These results demonstrate superior transient response and robust real-time power quality improvement compared to conventional PI-controlled UPQCs.

The International Journal of Maritime EngineeringVol. 168(A6(S))
GITAM University (IN)
Industry, innovation and infrastructure, Affordable and clean energy
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon