Synthetic Haematocrit for Myocardial Extracellular Volume Mapping in Clinical Practice at 1.5 T and 3 T

Background/Objectives: Synthetic haematocrit (HCT) permits cardiovascular magnetic resonance (CMR) extracellular volume fraction (ECV) estimation without contemporaneous laboratory HCT. We evaluated four published equations in a clinical referral cohort. Methods: This retrospective audit included 67 adults scanned at 1.5 T (n = 34) or 3 T (n = 33), with laboratory HCT within 24 h. Two equations per field strength were assessed using correlation and Bland–Altman analysis with confidence intervals. Observer reproducibility of T1 and calculated synthetic ECV was assessed using intraclass correlation coefficients (ICCs). Post hoc exploratory analyses examined classification at ECV ≥ 30%, estimation-error associations and proportional bias. Results: Absolute mean ECV bias was below one percentage point for all equations, but model-specific limits of agreement extended from −4.47 to 4.19 percentage points. At the exploratory 30% threshold, classification agreement was 85.3% and 88.2% at 1.5 T and 75.8% for both equations at 3 T. Synthetic ECV intraobserver ICCs ranged from 0.853 to 0.949; interobserver ICCs were 0.936–0.944 at 1.5 T and 0.842–0.851 at 3 T. Shang HCT showed magnitude-dependent disagreement. Conclusions: Synthetic ECV may help assess myocardial tissue when timely laboratory haematocrit is unavailable, with low average differences from conventional ECV. However, the small groups limit precision and generalisability, and individual and observer differences prevent assuming interchangeability. Local validation is needed before using synthetic ECV for clinical decisions or monitoring changes over time.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-13
DOI
https://doi.org/10.3390/diagnostics16223760
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Synthetic Haematocrit for Myocardial Extracellular Volume Mapping in Clinical Practice at 1.5 T and 3 T

Teresa Maria Capovilla, Gianfranco Sinagra, Gaetano Nucifora, Daniele Muser et al.
1 links
Diagnostics
Advanced MRI Techniques and Applications
article

Synthetic Haematocrit for Myocardial Extracellular Volume Mapping in Clinical Practice at 1.5 T and 3 T

Teresa Maria Capovilla, Gianfranco Sinagra, Gaetano Nucifora, Daniele Muser, Elif Ayduk Gövdeli, Mohamed Elzoghby
article en

Abstract

Background/Objectives: Synthetic haematocrit (HCT) permits cardiovascular magnetic resonance (CMR) extracellular volume fraction (ECV) estimation without contemporaneous laboratory HCT. We evaluated four published equations in a clinical referral cohort. Methods: This retrospective audit included 67 adults scanned at 1.5 T (n = 34) or 3 T (n = 33), with laboratory HCT within 24 h. Two equations per field strength were assessed using correlation and Bland–Altman analysis with confidence intervals. Observer reproducibility of T1 and calculated synthetic ECV was assessed using intraclass correlation coefficients (ICCs). Post hoc exploratory analyses examined classification at ECV ≥ 30%, estimation-error associations and proportional bias. Results: Absolute mean ECV bias was below one percentage point for all equations, but model-specific limits of agreement extended from −4.47 to 4.19 percentage points. At the exploratory 30% threshold, classification agreement was 85.3% and 88.2% at 1.5 T and 75.8% for both equations at 3 T. Synthetic ECV intraobserver ICCs ranged from 0.853 to 0.949; interobserver ICCs were 0.936–0.944 at 1.5 T and 0.842–0.851 at 3 T. Shang HCT showed magnitude-dependent disagreement. Conclusions: Synthetic ECV may help assess myocardial tissue when timely laboratory haematocrit is unavailable, with low average differences from conventional ECV. However, the small groups limit precision and generalisability, and individual and observer differences prevent assuming interchangeability. Local validation is needed before using synthetic ECV for clinical decisions or monitoring changes over time.

DiagnosticsVol. 16(22)
Humanitas University (IT), Guy's and St Thomas' NHS Foundation Trust (GB), Tanta University (EG), Manchester Academic Health Science Centre (GB), Harefield Hospital (GB), University of Manchester (GB), Manchester University NHS Foundation Trust (GB), Wythenshawe Hospital (GB), Azienda Sanitaria Universitaria Integrata di Trieste (IT)
Good health and well-being
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon