msiFlow 2.0: Extending Mass Spectrometry Imaging Workflows with Mass Recalibration, Annotation, Batch Correction, and Visual Quality Control

Mass spectrometry imaging (MSI) enables label-free, spatially resolved molecular profiling of tissues and cells, providing insights into physiological and pathological processes. However, its large and complex datasets require specialised computational approaches. We recently introduced msiFlow, an open source, end-to-end solution for reproducible and scalable MSI data analysis. Here, we present msiFlow 2.0, a major extension that integrates pixel-wise post-acquisition mass recalibration, automated lipid annotation, batch correction, and visual quality control, together with improved alignment, spatially informed deisotoping, and computational scalability. The workflow was evaluated using four human and mouse MALDI-2 and t-MALDI-2 MSI lipidomic datasets encompassing different biological conditions, sample types, and spatial resolutions. The updated computational mass recalibration and alignment workflow significantly improved mass accuracy of reported m/z values by correcting systematic mass deviations, achieving a mean absolute mass error below 1.5 ppm for independent MS/MS-supported lipid features. The integrated lipid annotation module reduced the number of unsupported candidate lipid assignments, while ComBat correction reduced sample-associated variation and retained separation of tissue compartments. Computational optimisation reduced alignment runtime by approximately 80%. Together, these advances provide an accurate, transparent, and scalable open-source framework for MSI data processing and downstream analysis.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-13
DOI
https://doi.org/10.64898/2026.11.11.765722
Primary Topic
Mass Spectrometry Techniques and Applications
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

msiFlow 2.0: Extending Mass Spectrometry Imaging Workflows with Mass Recalibration, Annotation, Batch Correction, and Visual Quality Control

Sven Brandau, Jens Soltwisch, Alexander Potthoff, Stephanie Thiebes et al.
2 links
bioRxiv (Cold Spring Harbor Laboratory)
Mass Spectrometry Techniques and Applications
preprint

msiFlow 2.0: Extending Mass Spectrometry Imaging Workflows with Mass Recalibration, Annotation, Batch Correction, and Visual Quality Control

Sven Brandau, Jens Soltwisch, Alexander Potthoff, Stephanie Thiebes, Philippa Spangenberg, Sebastian Bessler, Olga Shevchuk, Daniel Robert Engel, Jenny Bottek, Lars Widera, Eva-Maria Hanschmann
preprint en

Abstract

Mass spectrometry imaging (MSI) enables label-free, spatially resolved molecular profiling of tissues and cells, providing insights into physiological and pathological processes. However, its large and complex datasets require specialised computational approaches. We recently introduced msiFlow, an open source, end-to-end solution for reproducible and scalable MSI data analysis. Here, we present msiFlow 2.0, a major extension that integrates pixel-wise post-acquisition mass recalibration, automated lipid annotation, batch correction, and visual quality control, together with improved alignment, spatially informed deisotoping, and computational scalability. The workflow was evaluated using four human and mouse MALDI-2 and t-MALDI-2 MSI lipidomic datasets encompassing different biological conditions, sample types, and spatial resolutions. The updated computational mass recalibration and alignment workflow significantly improved mass accuracy of reported m/z values by correcting systematic mass deviations, achieving a mean absolute mass error below 1.5 ppm for independent MS/MS-supported lipid features. The integrated lipid annotation module reduced the number of unsupported candidate lipid assignments, while ComBat correction reduced sample-associated variation and retained separation of tissue compartments. Computational optimisation reduced alignment runtime by approximately 80%. Together, these advances provide an accurate, transparent, and scalable open-source framework for MSI data processing and downstream analysis.

bioRxiv (Cold Spring Harbor Laboratory)
University of Münster (DE), Essen University Hospital (DE)
Deutsche Forschungsgemeinschaft, Westfälische Wilhelms-Universität Münster, Universität Duisburg-Essen
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon