Two-Timescale Frequency Control of Grid-Forming Energy Storage in Islanded Microgrids Based on Meteorological Warnings

In islanded microgrids, a sudden drop in photovoltaic (PV) power causes severe frequency dips, whereas grid-forming energy storage relying on droop control alone exhibits a steady-state deviation that cannot be eliminated; increasing the damping coefficient converges only slowly and is constrained by the droop regulation ratio and the frequency deadband. To address this, this paper proposes a two-timescale frequency control method based on meteorological warnings. On the slow timescale, meteorological warnings are used to apply active-power feedforward against the PV drop caused by cloud passage, compressing the disturbance that droop must compensate from the entire power deficit to the prediction residual; on the fast timescale, virtual inertia and damping are pre-scheduled according to the bound of the prediction residual, raised before the disturbance and released afterwards. An input-to-state stability (ISS) theorem is established for the closed-loop system, proving that the frequency deviation is input-to-state stable with respect to the bounded prediction residual, from which the inertia/damping scheduling law and the feasible residual region are derived. Using a random forest predictor trained on three years of hourly measured meteorological data from a region in Hubei, together with a four-method benchmark and end-to-end ablation experiments, the results show that under an 85% PV drop the proposed method restores the steady-state frequency from 48.33 Hz to 50.00 Hz and reduces the maximum rate of change of frequency (RoCoF) in the fast transient from 0.81 Hz/s to 0.17 Hz/s with feedforward alone and to 0.06 Hz/s with the complete two-timescale controller; with a real event-level prediction error of 0.064, the steady-state compliance rate (not lower than 49.8 Hz) reaches 91.7% using the empirical event-level error distribution (94.4% under the Gaussian approximation), far above that of conventional droop control.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-13
DOI
https://doi.org/10.3390/en19225463
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Two-Timescale Frequency Control of Grid-Forming Energy Storage in Islanded Microgrids Based on Meteorological Warnings

Yuqi Ao, Kezheng Jiang, Xun Xu, Menghan Xiao et al.
3 links
Energies
Microgrid Control and Optimization
article

Two-Timescale Frequency Control of Grid-Forming Energy Storage in Islanded Microgrids Based on Meteorological Warnings

Yuqi Ao, Kezheng Jiang, Xun Xu, Menghan Xiao, Chang Ye
article en

Abstract

In islanded microgrids, a sudden drop in photovoltaic (PV) power causes severe frequency dips, whereas grid-forming energy storage relying on droop control alone exhibits a steady-state deviation that cannot be eliminated; increasing the damping coefficient converges only slowly and is constrained by the droop regulation ratio and the frequency deadband. To address this, this paper proposes a two-timescale frequency control method based on meteorological warnings. On the slow timescale, meteorological warnings are used to apply active-power feedforward against the PV drop caused by cloud passage, compressing the disturbance that droop must compensate from the entire power deficit to the prediction residual; on the fast timescale, virtual inertia and damping are pre-scheduled according to the bound of the prediction residual, raised before the disturbance and released afterwards. An input-to-state stability (ISS) theorem is established for the closed-loop system, proving that the frequency deviation is input-to-state stable with respect to the bounded prediction residual, from which the inertia/damping scheduling law and the feasible residual region are derived. Using a random forest predictor trained on three years of hourly measured meteorological data from a region in Hubei, together with a four-method benchmark and end-to-end ablation experiments, the results show that under an 85% PV drop the proposed method restores the steady-state frequency from 48.33 Hz to 50.00 Hz and reduces the maximum rate of change of frequency (RoCoF) in the fast transient from 0.81 Hz/s to 0.17 Hz/s with feedforward alone and to 0.06 Hz/s with the complete two-timescale controller; with a real event-level prediction error of 0.064, the steady-state compliance rate (not lower than 49.8 Hz) reaches 91.7% using the empirical event-level error distribution (94.4% under the Gaussian approximation), far above that of conventional droop control.

EnergiesVol. 19(22)
State Grid Hubei Electric Power Company Electric Power Research Institute (CN)
State Grid Hubei Electric Power Co
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon