Simultaneous Online Electrokinetic Sample Cleanup and Preconcentration in Capillary Zone Electrophoresis of Fluorophore-Labeled N-Glycans

Abstract Glycans play an essential role in the proper functioning of proteins, making them an important analyte of interest in the biomedical and biopharmaceutical fields. One of the most effective ways to analyze complex carbohydrates is by capillary electrophoresis, especially when stacking methods are employed. In addition, coupling with other electrokinetic-based options, such as simultaneous removal of interfering molecules from the sample matrix, is of high importance as well. The online stacking part of the method introduced in this paper is well suited for the preconcentration of fluorophore-labeled glycans. After hydrodynamic injection of the APTS labeling reaction mixture, the electric field was applied with the cathode at the injection side; thus, the neutral and positively charged molecules migrated toward the cathode according to the superimposed upstream electroosmotic flow (EOF) and electric force, while their negatively charged counterparts accumulated at the boundary of the sample plug and the background electrolyte. The polarity was then switched with the anode at the injection side, generating downstream EOF to carry the negatively charged fluorophore-labeled glycans toward the detection zone, while the unreacted APTS molecules and other negatively charged species with high electrophoretic mobilities migrated out of the capillary at the injection end. In this way, both sample preconcentration and purification were simultaneously achieved at the beginning of the separation process, alleviating the need for sample cleanup before analysis. The proposed method utilized a simple 150 mM MOPS-KOH (pH 7.2) background electrolyte, which provided high enough EOF and adequate conductivity difference to readily accomplish this dual task of purification and stacking, achieving more than an order of magnitude higher signal intensity and LOD in the sub-pM level.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-13
DOI
https://doi.org/10.1021/acs.analchem.6c03977
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Simultaneous Online Electrokinetic Sample Cleanup and Preconcentration in Capillary Zone Electrophoresis of Fluorophore-Labeled N-Glycans

Gábor Járvás, Rebeka Torok, Róbert Farsang, András Guttman et al.
2 links
Analytical Chemistry
Microfluidic and Capillary Electrophoresis Applications
article

Simultaneous Online Electrokinetic Sample Cleanup and Preconcentration in Capillary Zone Electrophoresis of Fluorophore-Labeled N-Glycans

Gábor Járvás, Rebeka Torok, Róbert Farsang, András Guttman, Kinga Hogyor
article en

Abstract

Abstract Glycans play an essential role in the proper functioning of proteins, making them an important analyte of interest in the biomedical and biopharmaceutical fields. One of the most effective ways to analyze complex carbohydrates is by capillary electrophoresis, especially when stacking methods are employed. In addition, coupling with other electrokinetic-based options, such as simultaneous removal of interfering molecules from the sample matrix, is of high importance as well. The online stacking part of the method introduced in this paper is well suited for the preconcentration of fluorophore-labeled glycans. After hydrodynamic injection of the APTS labeling reaction mixture, the electric field was applied with the cathode at the injection side; thus, the neutral and positively charged molecules migrated toward the cathode according to the superimposed upstream electroosmotic flow (EOF) and electric force, while their negatively charged counterparts accumulated at the boundary of the sample plug and the background electrolyte. The polarity was then switched with the anode at the injection side, generating downstream EOF to carry the negatively charged fluorophore-labeled glycans toward the detection zone, while the unreacted APTS molecules and other negatively charged species with high electrophoretic mobilities migrated out of the capillary at the injection end. In this way, both sample preconcentration and purification were simultaneously achieved at the beginning of the separation process, alleviating the need for sample cleanup before analysis. The proposed method utilized a simple 150 mM MOPS-KOH (pH 7.2) background electrolyte, which provided high enough EOF and adequate conductivity difference to readily accomplish this dual task of purification and stacking, achieving more than an order of magnitude higher signal intensity and LOD in the sub-pM level.

Analytical Chemistry
University of Debrecen (HU), University of Pannonia (HU)
Debreceni Egyetem, Nemzeti Kutatási Fejlesztési és Innovációs Hivatal, Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon