Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring
An 89-year-old man with structural deterioration of a surgical aortic bioprosthesis and renal dysfunction underwent zero-contrast transcatheter aortic valve-in-surgical valve (TAV-in-SAV) implantation. A SavvyWire provided continuous left ventricular pressure monitoring and rapid pacing during the procedure. After implantation of a 23-mm self-expanding valve, a residual transvalvular gradient was detected, prompting balloon postdilatation under rapid pacing. Repeat invasive hemodynamic assessment showed improvement, and echocardiography demonstrated a mean gradient of 12 mmHg. At 12 months, the patient was in New York Heart Association class I, with preserved renal function and a mean gradient of 8 mmHg. Continuous pressure monitoring may support intraprocedural assessment and guide valve optimization when contrast exposure is being avoided in patients with renal dysfunction.
Authors
- Yusuke Watanabe (ORCID: https://orcid.org/0000-0003-2297-5303)
- Joe Omiya
- Ken Kozuma (ORCID: https://orcid.org/0000-0003-3977-5973)
- Mizuki Miura (ORCID: https://orcid.org/0000-0003-3252-3861)
Institutions
- Teikyo University (JP)
Publication Details
- Journal
- Catheterization and Cardiovascular Interventions
- Published
- 2026-11-13
- DOI
- https://doi.org/10.1002/ccd.71010
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00