Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring

An 89-year-old man with structural deterioration of a surgical aortic bioprosthesis and renal dysfunction underwent zero-contrast transcatheter aortic valve-in-surgical valve (TAV-in-SAV) implantation. A SavvyWire provided continuous left ventricular pressure monitoring and rapid pacing during the procedure. After implantation of a 23-mm self-expanding valve, a residual transvalvular gradient was detected, prompting balloon postdilatation under rapid pacing. Repeat invasive hemodynamic assessment showed improvement, and echocardiography demonstrated a mean gradient of 12 mmHg. At 12 months, the patient was in New York Heart Association class I, with preserved renal function and a mean gradient of 8 mmHg. Continuous pressure monitoring may support intraprocedural assessment and guide valve optimization when contrast exposure is being avoided in patients with renal dysfunction.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-11-13
DOI
https://doi.org/10.1002/ccd.71010
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring

Yusuke Watanabe, Joe Omiya, Ken Kozuma, Mizuki Miura
1 links
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring

Yusuke Watanabe, Joe Omiya, Ken Kozuma, Mizuki Miura
article en

Abstract

An 89-year-old man with structural deterioration of a surgical aortic bioprosthesis and renal dysfunction underwent zero-contrast transcatheter aortic valve-in-surgical valve (TAV-in-SAV) implantation. A SavvyWire provided continuous left ventricular pressure monitoring and rapid pacing during the procedure. After implantation of a 23-mm self-expanding valve, a residual transvalvular gradient was detected, prompting balloon postdilatation under rapid pacing. Repeat invasive hemodynamic assessment showed improvement, and echocardiography demonstrated a mean gradient of 12 mmHg. At 12 months, the patient was in New York Heart Association class I, with preserved renal function and a mean gradient of 8 mmHg. Continuous pressure monitoring may support intraprocedural assessment and guide valve optimization when contrast exposure is being avoided in patients with renal dysfunction.

Catheterization and Cardiovascular Interventions
Teikyo University (JP)
Good health and well-being
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon