Crack-Enabled Tubular Graphene/SEBS Flexible Sensor for High-Sensitivity Strain–Temperature Sensing in Aqueous Environments

A multifunctional tubular flexible sensor was developed by forming a graphene/styrene-ethylene-butylene-styrene (SEBS) conductive layer on the inner wall of a commercial latex tube through solution mixing, syringe injection, solvent evaporation, and electrode assembly. The protected architecture combines crack-amplified piezoresistive strain sensing, temperature-dependent resistance, and aqueous-environment operation. The sensor exhibited piecewise strain sensitivity over 0–15%, with GF1 values of 11.95–32.74 and GF2 values of 20.24–84.63 across four different calibration specimens (n = 4), and retained distinguishable loading–unloading signals after 12,000 stretching cycles (0–15% strain). Under full immersion, heating from 25.9 to approximately 70 °C yielded an average apparent normalized temperature sensitivity of approximately 2.07% °C−1. After weak-acid and weak-alkali exposure for up to 3 d, representative short-term resistance fluctuations remained below 0.30%; static measurements in water at 8–70 °C remained below approximately 0.56%. Applications included wearable motion sensing, two-level temperature warning, robotic fruit recognition and size classification, and underwater Morse-code input. Segment-level evaluation yielded an overall accuracy of 73.94% for seven fruit classes and 86.3% for four nominal fruit-size classes. For the 52 underwater contact-event segments, the six-class recognition accuracy was 63.46%; when the six labels were collapsed into dot (point) and dash (line) groups, the derived binary accuracy was 71.2%. These application-level classification results are exploratory and do not establish generalization to independent recording sessions.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-13
DOI
https://doi.org/10.3390/s26227176
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Crack-Enabled Tubular Graphene/SEBS Flexible Sensor for High-Sensitivity Strain–Temperature Sensing in Aqueous Environments

Aobo Jiang, Hui Liu, Bo Liu, Jun Yuan et al.
2 links
Sensors
Advanced Sensor and Energy Harvesting Materials
article

Crack-Enabled Tubular Graphene/SEBS Flexible Sensor for High-Sensitivity Strain–Temperature Sensing in Aqueous Environments

Aobo Jiang, Hui Liu, Bo Liu, Jun Yuan, Donghan Li, Weilong Yan, Hongtao Liu, Zhenke Sun, Dongyan Huang, Jingxiang Wang
article en

Abstract

A multifunctional tubular flexible sensor was developed by forming a graphene/styrene-ethylene-butylene-styrene (SEBS) conductive layer on the inner wall of a commercial latex tube through solution mixing, syringe injection, solvent evaporation, and electrode assembly. The protected architecture combines crack-amplified piezoresistive strain sensing, temperature-dependent resistance, and aqueous-environment operation. The sensor exhibited piecewise strain sensitivity over 0–15%, with GF1 values of 11.95–32.74 and GF2 values of 20.24–84.63 across four different calibration specimens (n = 4), and retained distinguishable loading–unloading signals after 12,000 stretching cycles (0–15% strain). Under full immersion, heating from 25.9 to approximately 70 °C yielded an average apparent normalized temperature sensitivity of approximately 2.07% °C−1. After weak-acid and weak-alkali exposure for up to 3 d, representative short-term resistance fluctuations remained below 0.30%; static measurements in water at 8–70 °C remained below approximately 0.56%. Applications included wearable motion sensing, two-level temperature warning, robotic fruit recognition and size classification, and underwater Morse-code input. Segment-level evaluation yielded an overall accuracy of 73.94% for seven fruit classes and 86.3% for four nominal fruit-size classes. For the 52 underwater contact-event segments, the six-class recognition accuracy was 63.46%; when the six labels were collapsed into dot (point) and dash (line) groups, the derived binary accuracy was 71.2%. These application-level classification results are exploratory and do not establish generalization to independent recording sessions.

SensorsVol. 26(22)
Jilin Agricultural University (CN)
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon