Design and Validation of a Compact Sensor for Peripheral Pulse Waveform Capture

Peripheral pulse waveforms captured across different sites of the vascular tree provide valuable insights into cardiovascular health. This study presents a low-cost compact sensor designed to minimize intrusion at the measurement site while capturing the pulse waveform. The sensor performance was characterized and evaluated through both in-vitro benchtop experiments and a pilot in-vivo clinical study against invasive arterial pressure waveforms. The proposed sensor was able to capture pulse waveform morphology with reliable beat to beat tracking. Although offsets were present in the calculated features, fundamental temporal trends and cardiac cycle profiles were preserved. Thus, this work lays the foundation for a scalable hardware platform capable of multi-site pulse monitoring, enabling its integration with emerging computational frameworks for cardiovascular risk screening.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-13
DOI
https://doi.org/10.64898/2026.11.11.26367888
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design and Validation of a Compact Sensor for Peripheral Pulse Waveform Capture

Ruwan D. Ranaweera, K Divulwewa, Damsara Nandadeva, Janaka Wijayakulasooriya et al.
1 links
medRxiv
Non-Invasive Vital Sign Monitoring
preprint

Design and Validation of a Compact Sensor for Peripheral Pulse Waveform Capture

Ruwan D. Ranaweera, K Divulwewa, Damsara Nandadeva, Janaka Wijayakulasooriya, Ashani Ratnayake, A. J. A. Naim
preprint en

Abstract

Peripheral pulse waveforms captured across different sites of the vascular tree provide valuable insights into cardiovascular health. This study presents a low-cost compact sensor designed to minimize intrusion at the measurement site while capturing the pulse waveform. The sensor performance was characterized and evaluated through both in-vitro benchtop experiments and a pilot in-vivo clinical study against invasive arterial pressure waveforms. The proposed sensor was able to capture pulse waveform morphology with reliable beat to beat tracking. Although offsets were present in the calculated features, fundamental temporal trends and cardiac cycle profiles were preserved. Thus, this work lays the foundation for a scalable hardware platform capable of multi-site pulse monitoring, enabling its integration with emerging computational frameworks for cardiovascular risk screening.

medRxiv
University of Peradeniya (LK)
University of Peradeniya
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon