A flexible finger-shaped tactile sensor based on electrical impedance tomography

Abstract We developed a flexible, three-dimensional finger-shaped tactile sensor that maps contactinduced electrical changes using electrical impedance tomography (EIT). The 3D-printed device comprises a compliant resin body, a graphite–SiO2 powder sensing layer, and ten boundary electrodes. Electrode potentials were acquired as adjacent bias-electrode pairs were switched, and conductivity-change maps were reconstructed from the measurements. Point contact produced a decrease in reconstructed effective in-plane conductance near the contact and an increase in surrounding regions. Simultaneous two- and three-point contacts were distinguished at separations of approximately 6–7 mm or more. Potential acquisition took 2.1 ms, and data transfer plus reconstruction took 26.9 ms; without image rendering, maps could be updated at approximately 30-ms intervals. These results demonstrate the feasibility of near-real-time EIT tactile sensing with a compliant finger-shaped device.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2026-11-13
DOI
https://doi.org/10.35848/1347-4065/aec1e9
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A flexible finger-shaped tactile sensor based on electrical impedance tomography

Masatoshi Sakai, Takeru Tsuchihashi
1 links
Japanese Journal of Applied Physics
Electrical and Bioimpedance Tomography
article

A flexible finger-shaped tactile sensor based on electrical impedance tomography

Masatoshi Sakai, Takeru Tsuchihashi
article en

Abstract

Abstract We developed a flexible, three-dimensional finger-shaped tactile sensor that maps contactinduced electrical changes using electrical impedance tomography (EIT). The 3D-printed device comprises a compliant resin body, a graphite–SiO2 powder sensing layer, and ten boundary electrodes. Electrode potentials were acquired as adjacent bias-electrode pairs were switched, and conductivity-change maps were reconstructed from the measurements. Point contact produced a decrease in reconstructed effective in-plane conductance near the contact and an increase in surrounding regions. Simultaneous two- and three-point contacts were distinguished at separations of approximately 6–7 mm or more. Potential acquisition took 2.1 ms, and data transfer plus reconstruction took 26.9 ms; without image rendering, maps could be updated at approximately 30-ms intervals. These results demonstrate the feasibility of near-real-time EIT tactile sensing with a compliant finger-shaped device.

Japanese Journal of Applied Physics
Chiba University (JP)
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon