A Pre-Cooling System for a Venus Sample-Return Ascent Stage: Refrigeration Load and Time Sizing

This study sizes a Pre-Cooling System for a Venus Sample-Return Ascent Stage for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are pre-cooling target temperature of 290.0 kelvin, sensible cooling load of 60.4 kilowatt-hours, heat leak during cooling of 420.0 watts, cooling duration of 60.0 hours. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The system is a civilian science and construction design intended for a robotically serviced surface station.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24199757
Citations
1
Primary Topic
Spacecraft Design and Technology
Type
article
Field-Weighted Citation Impact
2.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Pre-Cooling System for a Venus Sample-Return Ascent Stage: Refrigeration Load and Time Sizing

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Spacecraft Design and Technology
2.00
article

A Pre-Cooling System for a Venus Sample-Return Ascent Stage: Refrigeration Load and Time Sizing

William Alexander Aldred
article en
1 citations

Abstract

This study sizes a Pre-Cooling System for a Venus Sample-Return Ascent Stage for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are pre-cooling target temperature of 290.0 kelvin, sensible cooling load of 60.4 kilowatt-hours, heat leak during cooling of 420.0 watts, cooling duration of 60.0 hours. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The system is a civilian science and construction design intended for a robotically serviced surface station.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 20%
Spacecraft Design and Technology
2.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon