Objectives: The distance between a light-curing tip and an orthodontic adhesive may alter the energy reaching the resin and affect polymerization-related mechanical performance. This study evaluated the effect of 0-, 5-, and 10-mm LED curing distances on resin microhardness, orthodontic bracket shear bond strength, and adhesive remnant index (ARI). Methods: Orthodontic resin was photoactivated for 10 s at 0, 5, or 10 mm. Vickers microhardness was measured in 90 independent resin specimens (30/group; three indentations/specimen) using a 5-N load for 5 s. In a separate tooth-based experiment, 45 extracted permanent human teeth received conventional metallic brackets. After 24 h of water storage, shear bond strength was tested at 1 mm/min and ARI was assessed microscopically. Results: Microhardness decreased from 50.01 ± 11.47 HV at 0 mm to 30.24 ± 7.49 HV at 5 mm and 25.03 ± 8.37 HV at 10 mm (p < 0.001). The difference between 5 and 10 mm was not statistically significant (p = 0.081). Shear bond strength decreased from 4.76 ± 1.31 MPa to 2.46 ± 0.92 MPa and 0.95 ± 0.69 MPa, respectively (p < 0.001). High ARI scores predominated, and the four-category ARI analysis did not detect a significant difference among groups (p = 0.270). Conclusions: Increasing LED curing-tip distance was associated with lower immediate microhardness and bracket bond strength. Microhardness was significantly lower at 5 and 10 mm than at 0 mm, whereas bond strength decreased significantly across all three distances. These outcomes were obtained in separate experimental systems and were interpreted as complementary rather than mechanistically linked. Clinically, the curing tip should be positioned as close and perpendicular to the bracket as access permits, while recognizing that these in vitro findings do not predict long-term bracket survival.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-11-13
DOI
https://doi.org/10.3390/dj14110746
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of LED Light-Curing Distance on Microhardness and Bracket Bonding Performance: An In Vitro Study

Carlos Alberto Jurado, Francisco X. Azpiazu‐Flores, René García‐Contreras, Benjamin Aranda‐Herrera et al.
Dentistry Journal
Dental materials and restorations
article

Effect of LED Light-Curing Distance on Microhardness and Bracket Bonding Performance: An In Vitro Study

Carlos Alberto Jurado, Francisco X. Azpiazu‐Flores, René García‐Contreras, Benjamin Aranda‐Herrera, Silvia Rojas‐Rueda, Rogelio José Scougall‐Vilchis, Roberto Ruíz-Díaz, Jose Vivaldi, Brissa Fuentes-Ortiz
article en

Abstract

Objectives: The distance between a light-curing tip and an orthodontic adhesive may alter the energy reaching the resin and affect polymerization-related mechanical performance. This study evaluated the effect of 0-, 5-, and 10-mm LED curing distances on resin microhardness, orthodontic bracket shear bond strength, and adhesive remnant index (ARI). Methods: Orthodontic resin was photoactivated for 10 s at 0, 5, or 10 mm. Vickers microhardness was measured in 90 independent resin specimens (30/group; three indentations/specimen) using a 5-N load for 5 s. In a separate tooth-based experiment, 45 extracted permanent human teeth received conventional metallic brackets. After 24 h of water storage, shear bond strength was tested at 1 mm/min and ARI was assessed microscopically. Results: Microhardness decreased from 50.01 ± 11.47 HV at 0 mm to 30.24 ± 7.49 HV at 5 mm and 25.03 ± 8.37 HV at 10 mm (p < 0.001). The difference between 5 and 10 mm was not statistically significant (p = 0.081). Shear bond strength decreased from 4.76 ± 1.31 MPa to 2.46 ± 0.92 MPa and 0.95 ± 0.69 MPa, respectively (p < 0.001). High ARI scores predominated, and the four-category ARI analysis did not detect a significant difference among groups (p = 0.270). Conclusions: Increasing LED curing-tip distance was associated with lower immediate microhardness and bracket bond strength. Microhardness was significantly lower at 5 and 10 mm than at 0 mm, whereas bond strength decreased significantly across all three distances. These outcomes were obtained in separate experimental systems and were interpreted as complementary rather than mechanistically linked. Clinically, the curing tip should be positioned as close and perpendicular to the bracket as access permits, while recognizing that these in vitro findings do not predict long-term bracket survival.

Dentistry JournalVol. 14(11)
Ponce Health Sciences University (PR), Universidad Autónoma del Estado de México (MX), The Ohio State University (US), Benemérita Universidad Autónoma de Puebla (MX), Universidad Nacional Autónoma de México (MX)
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon