Evaluation of bone-conducted sound during ear surgery: an in vivo pilot study

Abstract The impact of noise induced by drilling on hearing during ear operations has been discussed several times in the past. However, direct measurements of the equivalent sound pressure level in patients undergoing ear surgery have not previously been reported. This pilot study presents an easy-to-use method based on a calibrated accelerometer to determine the equivalent sound pressure level potentially applicable in the clinical routine. During seven monitored cochlear implant surgeries, the equivalent A-weighted sound pressure level L AF ranged from 111 to 126 dB(A) eqSPL at its maximum, whereas C-weighted peak levels L Cpeak showed peaks up to 140 dB(C) eqSPL . The recommended daily noise exposure limit was exceeded for three of the seven patients, suggesting the potential for drilling-induced temporal shifts in hearing threshold. Based on these findings, standardized noise monitoring is recommended as a quality assurance measure during otological surgery.

Authors

Institutions

Publication Details

Journal
BioMedical Engineering OnLine
Published
2026-11-13
DOI
https://doi.org/10.1186/s12938-026-01652-0
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of bone-conducted sound during ear surgery: an in vivo pilot study

Thomas Zahnert, Katarina Gille, Matthias Bornitz, Marcus Neudert et al.
BioMedical Engineering OnLine
Noise Effects and Management
article

Evaluation of bone-conducted sound during ear surgery: an in vivo pilot study

Thomas Zahnert, Katarina Gille, Matthias Bornitz, Marcus Neudert, Mario Fleischer
article en

Abstract

Abstract The impact of noise induced by drilling on hearing during ear operations has been discussed several times in the past. However, direct measurements of the equivalent sound pressure level in patients undergoing ear surgery have not previously been reported. This pilot study presents an easy-to-use method based on a calibrated accelerometer to determine the equivalent sound pressure level potentially applicable in the clinical routine. During seven monitored cochlear implant surgeries, the equivalent A-weighted sound pressure level L AF ranged from 111 to 126 dB(A) eqSPL at its maximum, whereas C-weighted peak levels L Cpeak showed peaks up to 140 dB(C) eqSPL . The recommended daily noise exposure limit was exceeded for three of the seven patients, suggesting the potential for drilling-induced temporal shifts in hearing threshold. Based on these findings, standardized noise monitoring is recommended as a quality assurance measure during otological surgery.

BioMedical Engineering OnLineVol. 25(1)
Humboldt-Universität zu Berlin (DE), University Hospital Carl Gustav Carus (DE), Charité - Universitätsmedizin Berlin (DE)
Bundesministerium für Bildung und Forschung, Technische Universität Dresden
Good health and well-being
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon