Artificial intelligence-enabled medical image analysis in photon-counting CT: A review of segmentation, detection, classification and characterization, and automated quantification

BackgroundPhoton-counting computed tomography (PCCT) provides finely sampled morphological images and energy-resolved products that may alter the behavior of artificial-intelligence models developed for conventional CT.ObjectiveThis review synthesizes downstream AI applications in PCCT and determines which study designs support claims of feasibility, transfer, spatial or spectral contribution, scanner advantage, and clinical utility.MethodsA structured narrative search identified original studies evaluating segmentation, detection, classification and characterization, and automated quantification on reconstructed PCCT images. Each analytical configuration was coded by task, effective input, model provenance, development or adaptation strategy, reference standard, comparator, testing independence, and evidence maturity.ResultsTechnical feasibility has been demonstrated across all four tasks. Established conventional-domain models often retained useful local performance on PCCT, while PCCT-native studies explored virtual monoenergetic images, threshold or energy-bin images, material maps, and multienergy feature spaces. However, small cohorts, repeated non-independent observations, incomplete external testing, limited matched PCCT-EID comparisons, and scarce spatial or spectral ablations restrict causal attribution. Prospective workflow evidence remains uncommon.ConclusionsPCCT creates important opportunities for AI-enabled image analysis, but availability of high-resolution or energy-resolved information does not establish its contribution to performance. Claims should be aligned with the comparator, ablation, reference standard, and validation design required to support them.

Authors

Institutions

Publication Details

Journal
Journal of X-Ray Science and Technology
Published
2026-11-13
DOI
https://doi.org/10.1177/08953996261506910
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Artificial intelligence-enabled medical image analysis in photon-counting CT: A review of segmentation, detection, classification and characterization, and automated quantification

Wanxia Deng, Jinghua Zhang, Yimin Yin, Jinyi Zhou et al.
Journal of X-Ray Science and Technology
Advanced X-ray and CT Imaging
article

Artificial intelligence-enabled medical image analysis in photon-counting CT: A review of segmentation, detection, classification and characterization, and automated quantification

Wanxia Deng, Jinghua Zhang, Yimin Yin, Jinyi Zhou, Shaohan Yu
article en

Abstract

BackgroundPhoton-counting computed tomography (PCCT) provides finely sampled morphological images and energy-resolved products that may alter the behavior of artificial-intelligence models developed for conventional CT.ObjectiveThis review synthesizes downstream AI applications in PCCT and determines which study designs support claims of feasibility, transfer, spatial or spectral contribution, scanner advantage, and clinical utility.MethodsA structured narrative search identified original studies evaluating segmentation, detection, classification and characterization, and automated quantification on reconstructed PCCT images. Each analytical configuration was coded by task, effective input, model provenance, development or adaptation strategy, reference standard, comparator, testing independence, and evidence maturity.ResultsTechnical feasibility has been demonstrated across all four tasks. Established conventional-domain models often retained useful local performance on PCCT, while PCCT-native studies explored virtual monoenergetic images, threshold or energy-bin images, material maps, and multienergy feature spaces. However, small cohorts, repeated non-independent observations, incomplete external testing, limited matched PCCT-EID comparisons, and scarce spatial or spectral ablations restrict causal attribution. Prospective workflow evidence remains uncommon.ConclusionsPCCT creates important opportunities for AI-enabled image analysis, but availability of high-resolution or energy-resolved information does not establish its contribution to performance. Claims should be aligned with the comparator, ablation, reference standard, and validation design required to support them.

Journal of X-Ray Science and Technology
Hohai University (CN), National University of Defense Technology (CN), Hunan First Normal University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province, Fundamental Research Funds for the Central Universities
Good health and well-being
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon