Two Tones From One Remnant: The 330 Mode, Its Separation From the Fundamental, and a Resolvability Criterion

Black-hole spectroscopy becomes a test, rather than a re-measurement, only when a second angular mode is resolved separately from the fundamental. This paper computes the frequency and damping of the l=m=3 mode for two representative remnants, evaluates the frequency separation against the natural linewidth set by the damping, and applies a Rayleigh-style criterion to state how much signal-to-noise ratio a genuine two-mode resolution requires. For the GW150914 remnant, the fundamental sits at 249.1 Hz and the 330 mode at 395.3 Hz, a ratio of 1.587 and a separation of 146.2 Hz. The mean natural linewidth of the two modes is 92.0 Hz, so the separation is 1.59 times the mean linewidth and the pair passes the Rayleigh-style criterion, though not by a wide margin. For the GW190521 remnant the 330 mode falls to 107.8 Hz with a separation of 39.7 Hz from its fundamental, in the part of the band where instrumental linewidth is no longer the only obstacle. The 330 mode of the GW150914 remnant lies at 395.3 Hz, separated from the fundamental by 146.2 Hz against a mean natural linewidth of 92.0 Hz, and resolving it alone at signal-to-noise ratio 8 requires a fundamental near 23. This study is computed from stated assumptions and published catalogue values; it is simulated, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24185450
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Two Tones From One Remnant: The 330 Mode, Its Separation From the Fundamental, and a Resolvability Criterion

William Alexander Aldred
6 links
Zenodo (CERN European Organization for Nuclear Research)
Pulsars and Gravitational Waves Research
article

Two Tones From One Remnant: The 330 Mode, Its Separation From the Fundamental, and a Resolvability Criterion

William Alexander Aldred
article en

Abstract

Black-hole spectroscopy becomes a test, rather than a re-measurement, only when a second angular mode is resolved separately from the fundamental. This paper computes the frequency and damping of the l=m=3 mode for two representative remnants, evaluates the frequency separation against the natural linewidth set by the damping, and applies a Rayleigh-style criterion to state how much signal-to-noise ratio a genuine two-mode resolution requires. For the GW150914 remnant, the fundamental sits at 249.1 Hz and the 330 mode at 395.3 Hz, a ratio of 1.587 and a separation of 146.2 Hz. The mean natural linewidth of the two modes is 92.0 Hz, so the separation is 1.59 times the mean linewidth and the pair passes the Rayleigh-style criterion, though not by a wide margin. For the GW190521 remnant the 330 mode falls to 107.8 Hz with a separation of 39.7 Hz from its fundamental, in the part of the band where instrumental linewidth is no longer the only obstacle. The 330 mode of the GW150914 remnant lies at 395.3 Hz, separated from the fundamental by 146.2 Hz against a mean natural linewidth of 92.0 Hz, and resolving it alone at signal-to-noise ratio 8 requires a fundamental near 23. This study is computed from stated assumptions and published catalogue values; it is simulated, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Pulsars and Gravitational Waves Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.