Explainable Machine Learning for Dataset-Defined Digital Eye Strain Risk Categories: Comparative Evaluation and Sensitivity Analysis

Background/Objectives: This study compared eight machine-learning classifiers for three dataset-defined digital eye strain (DES) categories and examined the robustness and interpretation of their predictions. Methods: A publicly available dataset containing 800 observations and 11 nonconstant predictors was analyzed using training-only preprocessing, repeated stratified cross-validation, randomized hyperparameter optimization, and an 80:20 stratified train–test split. Additional analyses included nested cross-validation of support vector machine (SVM) and logistic regression (LR), feature ablation, probability calibration, and SHAP-based interpretation. Results: SVM achieved the highest mean repeated-CV macro-F1 (0.9861). On the held-out test set, SVM achieved 0.9625 accuracy and 0.9636 macro-F1, while LR achieved 0.9688 and 0.9714, respectively. Nested-CV macro-F1 values were similar for SVM (0.9777) and LR (0.9768). Excluding symptom-related predictors reduced test macro-F1 to 0.5141 (SVM) and 0.4902 (LR); additionally, excluding daily screen time reduced these values to 0.3714 and 0.3724. Multiclass Brier scores were 0.0506 for SVM and 0.0456 for LR. Screen time and ocular symptoms also contributed prominently to SHAP explanations. Conclusions: Classification performance depended strongly on symptom and screen-exposure variables. The reported metrics quantify agreement with dataset-defined labels, not clinical diagnostic accuracy or the ability to predict future DES risk. The label-generation criteria are undocumented, supporting clinical gold-standard evidence is unavailable, and potential overlap between predictors and label-generation criteria cannot be excluded. Without validation against independently established clinical outcomes and in external populations, these findings remain dataset-specific classification results and do not establish real-world clinical risk-prediction capability.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-11-13
DOI
https://doi.org/10.3390/bioengineering13111348
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Explainable Machine Learning for Dataset-Defined Digital Eye Strain Risk Categories: Comparative Evaluation and Sensitivity Analysis

İrem Şenyer Yapıcı, Rukiye Uzun Arslan, Tuğba Özge Onur
2 links
Bioengineering
Ergonomics and Musculoskeletal Disorders
article

Explainable Machine Learning for Dataset-Defined Digital Eye Strain Risk Categories: Comparative Evaluation and Sensitivity Analysis

İrem Şenyer Yapıcı, Rukiye Uzun Arslan, Tuğba Özge Onur
article en

Abstract

Background/Objectives: This study compared eight machine-learning classifiers for three dataset-defined digital eye strain (DES) categories and examined the robustness and interpretation of their predictions. Methods: A publicly available dataset containing 800 observations and 11 nonconstant predictors was analyzed using training-only preprocessing, repeated stratified cross-validation, randomized hyperparameter optimization, and an 80:20 stratified train–test split. Additional analyses included nested cross-validation of support vector machine (SVM) and logistic regression (LR), feature ablation, probability calibration, and SHAP-based interpretation. Results: SVM achieved the highest mean repeated-CV macro-F1 (0.9861). On the held-out test set, SVM achieved 0.9625 accuracy and 0.9636 macro-F1, while LR achieved 0.9688 and 0.9714, respectively. Nested-CV macro-F1 values were similar for SVM (0.9777) and LR (0.9768). Excluding symptom-related predictors reduced test macro-F1 to 0.5141 (SVM) and 0.4902 (LR); additionally, excluding daily screen time reduced these values to 0.3714 and 0.3724. Multiclass Brier scores were 0.0506 for SVM and 0.0456 for LR. Screen time and ocular symptoms also contributed prominently to SHAP explanations. Conclusions: Classification performance depended strongly on symptom and screen-exposure variables. The reported metrics quantify agreement with dataset-defined labels, not clinical diagnostic accuracy or the ability to predict future DES risk. The label-generation criteria are undocumented, supporting clinical gold-standard evidence is unavailable, and potential overlap between predictors and label-generation criteria cannot be excluded. Without validation against independently established clinical outcomes and in external populations, these findings remain dataset-specific classification results and do not establish real-world clinical risk-prediction capability.

BioengineeringVol. 13(11)
Zonguldak Bülent Ecevit University (TR)
Good health and well-being
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon