DIFFERENCES IN FASTING BLOOD GLUCOSE LEVELS BETWEEN SERUM AND EDTA PLASMA

Blood glucose testing is influenced by the type of specimen used. Serum is generally used in clinical chemistry testing, whilst EDTA plasma is used less frequently and is generally restricted to specific conditions. Previous studies have predominantly compared random blood glucose levels; therefore, a specific study on fasting blood glucose is required. The aim of this study was to determine the differences in fasting blood glucose levels between serum and EDTA plasma. This quantitative study, employing an analytical observational design and a cross-sectional approach, was conducted at the Prameka Clinical Laboratory between November 2025 and March 2026, with samples collected in February–March 2026. The sample comprised 30 adult patients aged 18–59 years, selected using purposive sampling. Serum and EDTA plasma samples were obtained from each respondent. Glucose testing was carried out using the GOD-PAP method with a Dirui CS-T180 analyser. Analysis was performed using SPSS via the Shapiro–Wilk test and the Paired Sample t-test. The mean fasting blood glucose level in serum was 105.120 mg/dL, whilst in EDTA plasma it was 110.993 mg/dL. The Paired Sample t-test yielded a t-value of −13.839 and p = 0.000, indicating a significant difference between the two specimen types. The conclusion of this study is that fasting blood glucose levels in EDTA plasma tend to be higher than those in serum. Consistency in the use of specimen types is required to avoid discrepancies in the interpretation of laboratory results and to support the accuracy of clinical monitoring.

Authors

Institutions

Publication Details

Journal
Multidisciplinary Indonesian Center Journal
Published
2026-11-13
DOI
https://doi.org/10.62567/micjo.v3i4.3132
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DIFFERENCES IN FASTING BLOOD GLUCOSE LEVELS BETWEEN SERUM AND EDTA PLASMA

Sri Idayani, Didik Prasetya, I Gusti Ayu Agung Aristania Febriyanti
1 links
Multidisciplinary Indonesian Center Journal
Clinical Laboratory Practices and Quality Control
article

DIFFERENCES IN FASTING BLOOD GLUCOSE LEVELS BETWEEN SERUM AND EDTA PLASMA

Sri Idayani, Didik Prasetya, I Gusti Ayu Agung Aristania Febriyanti
article en

Abstract

Blood glucose testing is influenced by the type of specimen used. Serum is generally used in clinical chemistry testing, whilst EDTA plasma is used less frequently and is generally restricted to specific conditions. Previous studies have predominantly compared random blood glucose levels; therefore, a specific study on fasting blood glucose is required. The aim of this study was to determine the differences in fasting blood glucose levels between serum and EDTA plasma. This quantitative study, employing an analytical observational design and a cross-sectional approach, was conducted at the Prameka Clinical Laboratory between November 2025 and March 2026, with samples collected in February–March 2026. The sample comprised 30 adult patients aged 18–59 years, selected using purposive sampling. Serum and EDTA plasma samples were obtained from each respondent. Glucose testing was carried out using the GOD-PAP method with a Dirui CS-T180 analyser. Analysis was performed using SPSS via the Shapiro–Wilk test and the Paired Sample t-test. The mean fasting blood glucose level in serum was 105.120 mg/dL, whilst in EDTA plasma it was 110.993 mg/dL. The Paired Sample t-test yielded a t-value of −13.839 and p = 0.000, indicating a significant difference between the two specimen types. The conclusion of this study is that fasting blood glucose levels in EDTA plasma tend to be higher than those in serum. Consistency in the use of specimen types is required to avoid discrepancies in the interpretation of laboratory results and to support the accuracy of clinical monitoring.

Multidisciplinary Indonesian Center JournalVol. 3(4)
STIKes Wira Medika Bali (ID)
Good health and well-being
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon