A Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere: Buoyancy and Tether Sizing

This study sizes a Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are float altitude of 12000.0 metres, ambient pressure at float altitude of 22.1 bar, ambient temperature at float altitude of 639.0 kelvin, net lift per cubic metre of 1.454 kilograms. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The system is a civilian science and construction design intended for a robotically serviced surface station.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24199556
Citations
1
Primary Topic
Aerospace Engineering and Energy Systems
Type
article
Field-Weighted Citation Impact
2.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere: Buoyancy and Tether Sizing

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Aerospace Engineering and Energy Systems
2.00
article

A Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere: Buoyancy and Tether Sizing

William Alexander Aldred
article en
1 citations

Abstract

This study sizes a Surface-Linked Hot-Gas Balloon Station for the Venus Deep Atmosphere for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are float altitude of 12000.0 metres, ambient pressure at float altitude of 22.1 bar, ambient temperature at float altitude of 639.0 kelvin, net lift per cubic metre of 1.454 kilograms. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The system is a civilian science and construction design intended for a robotically serviced surface station.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 20%
Aerospace Engineering and Energy Systems
2.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon