Design Blueprint: Passive Radiative Cooling Panels for Lunar Daytime Equipment Temperature Control
Design blueprint derived from the source paper (DOI 10.5281/zenodo.24189133): This study sizes passive radiative cooling panels operating in lunar daylight: a panel at 300 kelvin emits 436 watts per square metre, absorbs 109 watts of sunlight at the stated absorptance, and after a stated regolith infrared load delivers a net cooling flux of 267 watts per square metre, so a 10 kilowatt cooling duty needs 37 square metres. Sizing follows from computed thermal budgets derived in the study. This is a computed study with no targeting or weapon application. The work is simulated and computed from stated assumptions, not measured. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-13
- DOI
- https://doi.org/10.5281/zenodo.24190259
- Primary Topic
- Thermal Radiation and Cooling Technologies
- Type
- preprint