Design Blueprint: Passive Radiative Cooling Panels for Lunar Daytime Equipment Temperature Control

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24189133): This study sizes passive radiative cooling panels operating in lunar daylight: a panel at 300 kelvin emits 436 watts per square metre, absorbs 109 watts of sunlight at the stated absorptance, and after a stated regolith infrared load delivers a net cooling flux of 267 watts per square metre, so a 10 kilowatt cooling duty needs 37 square metres. Sizing follows from computed thermal budgets derived in the study. This is a computed study with no targeting or weapon application. The work is simulated and computed from stated assumptions, not measured. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24190259
Primary Topic
Thermal Radiation and Cooling Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design Blueprint: Passive Radiative Cooling Panels for Lunar Daytime Equipment Temperature Control

William Alexander Aldred
9 links
Zenodo (CERN European Organization for Nuclear Research)
Thermal Radiation and Cooling Technologies
preprint

Design Blueprint: Passive Radiative Cooling Panels for Lunar Daytime Equipment Temperature Control

William Alexander Aldred
preprint en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24189133): This study sizes passive radiative cooling panels operating in lunar daylight: a panel at 300 kelvin emits 436 watts per square metre, absorbs 109 watts of sunlight at the stated absorptance, and after a stated regolith infrared load delivers a net cooling flux of 267 watts per square metre, so a 10 kilowatt cooling duty needs 37 square metres. Sizing follows from computed thermal budgets derived in the study. This is a computed study with no targeting or weapon application. The work is simulated and computed from stated assumptions, not measured. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Thermal Radiation and Cooling Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon