A Dust-Derated Photovoltaic Array for a Mars Surface Habitat: Sizing from the Martian Solar Budget

This paper presents a sized design for a Mars surface system based on photovoltaic conversion in triple-junction cells, with maximum-power-point conditioning and dust derating. A fixed-tilt triple-junction photovoltaic array feeding a conditioned direct-current bus for a four-person habitat. The study is SIMULATED, NOT MEASURED: all values are computed from stated assumptions and published Martian environmental data, and no hardware was built or tested. The principal computed results are solar constant W m2 of 590, atmospheric transmission of 0.75, peak irradiance W m2 of 442.5, cell efficiency of 0.3. Further results include dust factor of 0.78, specific power W m2 of 100.4, design load kW of 18, array area m2 of 179.2. The design is a computed study for peaceful surface operations — power supply, thermal control, radiation protection, construction and resource extraction for a crewed base — and it has no targeting or weapon application. Losses, deratings for dust and temperature, and the margin between capacity and the stated load are reported alongside the headline figures, and the limitations section states what a physical test would still need to establish.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24193685
Citations
1
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Dust-Derated Photovoltaic Array for a Mars Surface Habitat: Sizing from the Martian Solar Budget

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Photovoltaic System Optimization Techniques
0.80
article

A Dust-Derated Photovoltaic Array for a Mars Surface Habitat: Sizing from the Martian Solar Budget

William Alexander Aldred
article en
1 citations

Abstract

This paper presents a sized design for a Mars surface system based on photovoltaic conversion in triple-junction cells, with maximum-power-point conditioning and dust derating. A fixed-tilt triple-junction photovoltaic array feeding a conditioned direct-current bus for a four-person habitat. The study is SIMULATED, NOT MEASURED: all values are computed from stated assumptions and published Martian environmental data, and no hardware was built or tested. The principal computed results are solar constant W m2 of 590, atmospheric transmission of 0.75, peak irradiance W m2 of 442.5, cell efficiency of 0.3. Further results include dust factor of 0.78, specific power W m2 of 100.4, design load kW of 18, array area m2 of 179.2. The design is a computed study for peaceful surface operations — power supply, thermal control, radiation protection, construction and resource extraction for a crewed base — and it has no targeting or weapon application. Losses, deratings for dust and temperature, and the margin between capacity and the stated load are reported alongside the headline figures, and the limitations section states what a physical test would still need to establish.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 35%
Photovoltaic System Optimization Techniques
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon