Noise2Flow: single-image conditional mean denoising flows from weak-anchor couplings

PurposeSingle-image denoising is needed when clean targets and repeated acquisitions are unavailable, as in low-dose computed tomography (CT) and fluorescence microscopy. Existing per-image methods often assume pixel-wise noise independence, which fails under spatially correlated noise, and imperfect single-image denoisers commonly leave residual noise. We learn a proxy mean-velocity direction field from one noisy image so that a single transport step exceeds the imperfect anchors used as supervision.ApproachNoise2Flow runs weak single-image denoisers on the noisy image to form source–target couplings. The displacement from input to anchor is a directional proxy for the mean restoration velocity. For each imposed linear segment, MeanFlow’s finite-interval average velocity reduces exactly to a constant secant. A flow network is trained with a direction-normalized objective that regularizes predictions at states in a stochastic tube around the noisy-to-anchor segment toward a common secant direction. At inference, the weak denoisers are discarded; one update with a calibrated transport budget restores the image.ResultsOn the fluorescence microscopy denoising (FMD) test set of 48 images, Noise2Flow reaches 34.91 dB peak signal-to-noise ratio and 0.887 structural similarity, 0.52 dB above Filter2Noise, and 1.00 dB above Noise2Detail. On 1311 low-dose CT slices from 10 Mayo Clinic patients, it reaches 28.82 dB and 0.714, 0.91 dB above Filter2Noise and 1.23 dB above Noise2Detail. One-step inference is within 0.11 dB of 10-step Heun; tube sampling improves the 10-step Heun result relative to on-segment training; a calibrated extrapolation factor moves the flow past residual-noise anchors of varying quality.ConclusionsA proxy mean-velocity direction field can be learned from a single noisy medical image by treating weak-denoiser outputs as directional anchors rather than final targets. The straight proxy path defines the one-step endpoint update; tube regularization and calibrated extrapolation carry that update past residual-noise anchors. The learned flow exceeds residual-noise anchors and supports reference-free restoration in data-limited imaging.

Authors

Institutions

Publication Details

Journal
Journal of medical imaging
Published
2026-11-13
DOI
https://doi.org/10.1117/1.jmi.13.6.064002
Primary Topic
Image and Signal Denoising Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Noise2Flow: single-image conditional mean denoising flows from weak-anchor couplings

Linda-Sophie Schneider, Mingxuan Gu, Zijin Yang, Siming Bayer et al.
1 links
Journal of medical imaging
Image and Signal Denoising Methods
article

Noise2Flow: single-image conditional mean denoising flows from weak-anchor couplings

Linda-Sophie Schneider, Mingxuan Gu, Zijin Yang, Siming Bayer, Daiqi Liu, Linghan Cai, Andreas Maier, Ge Hu, Siyuan Mei, Y. J. Sun, Chengze Ye, Lan Song, Fei Wu
article en

Abstract

PurposeSingle-image denoising is needed when clean targets and repeated acquisitions are unavailable, as in low-dose computed tomography (CT) and fluorescence microscopy. Existing per-image methods often assume pixel-wise noise independence, which fails under spatially correlated noise, and imperfect single-image denoisers commonly leave residual noise. We learn a proxy mean-velocity direction field from one noisy image so that a single transport step exceeds the imperfect anchors used as supervision.ApproachNoise2Flow runs weak single-image denoisers on the noisy image to form source–target couplings. The displacement from input to anchor is a directional proxy for the mean restoration velocity. For each imposed linear segment, MeanFlow’s finite-interval average velocity reduces exactly to a constant secant. A flow network is trained with a direction-normalized objective that regularizes predictions at states in a stochastic tube around the noisy-to-anchor segment toward a common secant direction. At inference, the weak denoisers are discarded; one update with a calibrated transport budget restores the image.ResultsOn the fluorescence microscopy denoising (FMD) test set of 48 images, Noise2Flow reaches 34.91 dB peak signal-to-noise ratio and 0.887 structural similarity, 0.52 dB above Filter2Noise, and 1.00 dB above Noise2Detail. On 1311 low-dose CT slices from 10 Mayo Clinic patients, it reaches 28.82 dB and 0.714, 0.91 dB above Filter2Noise and 1.23 dB above Noise2Detail. One-step inference is within 0.11 dB of 10-step Heun; tube sampling improves the 10-step Heun result relative to on-segment training; a calibrated extrapolation factor moves the flow past residual-noise anchors of varying quality.ConclusionsA proxy mean-velocity direction field can be learned from a single noisy medical image by treating weak-denoiser outputs as directional anchors rather than final targets. The straight proxy path defines the one-step endpoint update; tube regularization and calibrated extrapolation carry that update past residual-noise anchors. The learned flow exceeds residual-noise anchors and supports reference-free restoration in data-limited imaging.

Journal of medical imagingVol. 13(06)
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Harbin Institute of Technology (CN), Peking Union Medical College Hospital (CN)
Image and Signal Denoising Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon