Demand-Profile Effects on PV Self-Consumption and Battery Storage Performance: Five Mediterranean Case Studies

This study evaluates photovoltaic (PV) self-production with and without battery energy storage for five contrasting consumer profiles under the meteorological conditions considered for Crete, Greece: a university campus, an aquarium, an industrial facility, a residential group and a travel agency. Annual chronological simulations at hourly resolution assess demand coverage, surplus generation and economic performance over a 25-year evaluation period, with no revenue assigned to surplus electricity. The model includes battery charging and discharging power limits, annual degradation rates of 0.5% for PV power capacity and 2% for battery energy capacity, and equipment replacement assumptions. Normalised generation and storage parameters facilitate comparison across cases. A one-at-a-time sensitivity analysis examines six technical and economic parameters for one selected configuration per consumer. Without storage, the tested configurations supply 36.1–45.8% of annual demand at the university, 36.5% at the aquarium, 47.7–67.3% at the industrial facility, 24.2–29.2% in the residential group and 50.2–55.1% at the travel agency. Among the reported configurations, those achieving the highest mean annual demand coverage in each case supply 89.5–94.6% of demand, while retaining surplus fractions of 20.1–77.1%. In the residential case, increasing PV capacity from 500 to 1000 kW at a fixed storage capacity of 1000 kWh raises coverage by only 2.6 percentage points, while surplus increases from 55.3% to 77.1%. Degradation affects useful supply differently from nominal asset performance: surplus generation buffers the decline in direct PV supply, whereas battery degradation generally drives the reduction in total coverage. Economic outcomes are particularly sensitive to electricity purchase price and demand level, with the residential and travel agency configurations showing greater dependence on favorable economic assumptions. The findings support joint PV–battery sizing based on demand timing and marginal useful energy gains, rather than annual energy matching or maximum coverage alone.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-13
DOI
https://doi.org/10.3390/en19225470
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Demand-Profile Effects on PV Self-Consumption and Battery Storage Performance: Five Mediterranean Case Studies

Ioannis E. Papadakis, Nikolaos C. Papadakis, George Viskadouros, George M. Stavrakakis et al.
1 links
Energies
Power Systems and Renewable Energy
article

Demand-Profile Effects on PV Self-Consumption and Battery Storage Performance: Five Mediterranean Case Studies

Ioannis E. Papadakis, Nikolaos C. Papadakis, George Viskadouros, George M. Stavrakakis, Dimitris Al. Katsaprakakis, Marina Leontidi, Nikos Kallitsounakis
article en

Abstract

This study evaluates photovoltaic (PV) self-production with and without battery energy storage for five contrasting consumer profiles under the meteorological conditions considered for Crete, Greece: a university campus, an aquarium, an industrial facility, a residential group and a travel agency. Annual chronological simulations at hourly resolution assess demand coverage, surplus generation and economic performance over a 25-year evaluation period, with no revenue assigned to surplus electricity. The model includes battery charging and discharging power limits, annual degradation rates of 0.5% for PV power capacity and 2% for battery energy capacity, and equipment replacement assumptions. Normalised generation and storage parameters facilitate comparison across cases. A one-at-a-time sensitivity analysis examines six technical and economic parameters for one selected configuration per consumer. Without storage, the tested configurations supply 36.1–45.8% of annual demand at the university, 36.5% at the aquarium, 47.7–67.3% at the industrial facility, 24.2–29.2% in the residential group and 50.2–55.1% at the travel agency. Among the reported configurations, those achieving the highest mean annual demand coverage in each case supply 89.5–94.6% of demand, while retaining surplus fractions of 20.1–77.1%. In the residential case, increasing PV capacity from 500 to 1000 kW at a fixed storage capacity of 1000 kWh raises coverage by only 2.6 percentage points, while surplus increases from 55.3% to 77.1%. Degradation affects useful supply differently from nominal asset performance: surplus generation buffers the decline in direct PV supply, whereas battery degradation generally drives the reduction in total coverage. Economic outcomes are particularly sensitive to electricity purchase price and demand level, with the residential and travel agency configurations showing greater dependence on favorable economic assumptions. The findings support joint PV–battery sizing based on demand timing and marginal useful energy gains, rather than annual energy matching or maximum coverage alone.

EnergiesVol. 19(22)
Hellenic Mediterranean University (GR), Hellenic Centre for Marine Research (GR)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon