Sim&Size versus IFU-Based Sizing for the Artisse 2.0 Intrasaccular Device in a Multicenter Registry

BACKGROUND AND PURPOSE: Virtual simulation is increasingly promoted for intrasaccular device sizing, but whether it changes device selection or procedural outcomes for new, highly conformable devices is unknown. We compared Sim&Size simulation with instructions-for-use (IFU) chart sizing for the Artisse 2.0 in early multicenter experience. MATERIALS AND METHODS: We retrospectively analyzed data from the INSPIRE-A registry (November 2022-June 2024). Sim&Size use depended on software availability. We assessed agreement between sizing tools, technical success, first-device success, adjunctive devices, procedure and fluoroscopy times, complications, and the cause of each technical failure. RESULTS: Sim&Size was used in 88/123 cases (71.5%). When both methods were used (n=59), the same device was selected in 54 (91.5%). Technical success was 98.9% with Sim&Size and 85.7% without (p=0.007), whereas first-device success (86.4% vs 80.0%, p=0.41) and procedure and fluoroscopy times did not differ. Perioperative complications occurred in 4/123 (3.3%). Of the six technical failures, five were related to device fit, mostly in anatomies at the limits of the device range, and one resulted from a perforation before deployment. A dome-to-neck ratio <1 was associated with failure (3/7 vs 3/116, p=0.002). CONCLUSIONS: For the Artisse 2.0, Sim&Size and chart-based sizing selected the same device in most cases. Sim&Size use was associated with higher technical success, whereas first-device success and procedure and fluoroscopy times were comparable. Both approaches achieved high procedural success with a low complication rate and may be used according to operator preference, with simulation potentially most useful in anatomies at the limits of the device range.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-11-13
DOI
https://doi.org/10.3174/ajnr.a9716
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sim&Size versus IFU-Based Sizing for the Artisse 2.0 Intrasaccular Device in a Multicenter Registry

Ricardó A. Hanel, Markus Alfred Möhlenbruch, Laurent Spelle, Jonathan Cortese et al.
1 links
American Journal of Neuroradiology
Intracranial Aneurysms: Treatment and Complications
article

Sim&Size versus IFU-Based Sizing for the Artisse 2.0 Intrasaccular Device in a Multicenter Registry

Ricardó A. Hanel, Markus Alfred Möhlenbruch, Laurent Spelle, Jonathan Cortese, Fernanda Rodriguez‐Erazú, Riitta Rautio, Saleh M. Lamin, Salvador F. Gutierrez‐Aguirre, Monika Killer‐Oberpfalzer, Otavio Frederico De Toledo, Jens Fiehler
article en

Abstract

BACKGROUND AND PURPOSE: Virtual simulation is increasingly promoted for intrasaccular device sizing, but whether it changes device selection or procedural outcomes for new, highly conformable devices is unknown. We compared Sim&Size simulation with instructions-for-use (IFU) chart sizing for the Artisse 2.0 in early multicenter experience. MATERIALS AND METHODS: We retrospectively analyzed data from the INSPIRE-A registry (November 2022-June 2024). Sim&Size use depended on software availability. We assessed agreement between sizing tools, technical success, first-device success, adjunctive devices, procedure and fluoroscopy times, complications, and the cause of each technical failure. RESULTS: Sim&Size was used in 88/123 cases (71.5%). When both methods were used (n=59), the same device was selected in 54 (91.5%). Technical success was 98.9% with Sim&Size and 85.7% without (p=0.007), whereas first-device success (86.4% vs 80.0%, p=0.41) and procedure and fluoroscopy times did not differ. Perioperative complications occurred in 4/123 (3.3%). Of the six technical failures, five were related to device fit, mostly in anatomies at the limits of the device range, and one resulted from a perforation before deployment. A dome-to-neck ratio <1 was associated with failure (3/7 vs 3/116, p=0.002). CONCLUSIONS: For the Artisse 2.0, Sim&Size and chart-based sizing selected the same device in most cases. Sim&Size use was associated with higher technical success, whereas first-device success and procedure and fluoroscopy times were comparable. Both approaches achieved high procedural success with a low complication rate and may be used according to operator preference, with simulation potentially most useful in anatomies at the limits of the device range.

American Journal of Neuroradiology
Inserm (FR), University of Turku (FI), Heidelberg University (DE), Université Paris-Saclay (FR), Turku University Hospital (FI), University Hospital Heidelberg (DE), Jacksonville University (US), University Medical Center Hamburg-Eppendorf (DE), Bicêtre Hospital (FR)
Good health and well-being
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon