An H-Bridge-Based Battery ACIR Measurement System with Energy Recovery

Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-11-13
DOI
https://doi.org/10.3390/electronics15225283
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An H-Bridge-Based Battery ACIR Measurement System with Energy Recovery

Hongyun Zhao, Liqun He, Atif Iqbal, Liqin Yan et al.
Electronics
Battery Modeling and Management
article

An H-Bridge-Based Battery ACIR Measurement System with Energy Recovery

Hongyun Zhao, Liqun He, Atif Iqbal, Liqin Yan, Shiyi Shao, Kefu Liu, Rongrong Zhang, Cheng Wang, Jingying Xie, Zhaohui Jin, Jian Qiu, Xiaobing Lao
article en

Abstract

Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.

ElectronicsVol. 15(22)
Shanghai Jiao Tong University (CN), Fudan University (CN), Nanjing University of Science and Technology (CN), Soochow University (CN), China State Shipbuilding (China) (CN), Qatar University (QA)
Shanghai Academy of Spaceflight Technology
Affordable and clean energy
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon