Double probes and weak double layers share an exact recurrence but not their physics: log-frequency scales, presheath energetics and the limits of bifurcation overlays

In log-odds the floating double-probe characteristic is an exact translation, and on any uniform bias grid it is an exact Beverton–Holt map. This paper works out what that exactness implies when bias is counted in nats (eV /Te), current as a share of the ion supply, and rates on a logarithmic axis. The multipliers of the map telescope to zero net expansion; an error in the starting value moves only the inferred floating point; and the probe’s response rate is u = u∗ + ln y(1 − y), so in the wings one e-fold of bias costs one e-fold of rate. A dwell schedule built on that ladder gives the same error per nat at every sample and a 4.6-fold shorter sweep for a typical probe. The factor 1 + GR both inflates the apparent temperature and divides the stable integration step, and a double probe in any passive circuit needs zero bits of feedback. Up–down residuals in log-odds separate capacitive current, contamination layers and drift by shape, with no fitted parameter. Read in nats, the presheath is an isothermal engine with efficiency η = 1/(2Φps), about 0.63 for a measured argon presheath. The sheath is a Boltzmann gate, and the only demon (a feedback element that senses a flux imbalance at the boundary and acts to correct it) that needs information is the friction that locks two ion species, which requires Φps ≥ 1 2 ⟨m⟩⟨1/m⟩: 1.51 nats for a balanced Ar–He mix. Archival thesis data on the Ar–He presheath instability are consistent with this cost if Te ≲ 3 eV. A weak double layer obeys the same recurrence as the double probe, but with a map parameter that scales with the layer’s drop rather than with Te. Finally, a logistic cascade overlaid on a trace or profile belongs to the forward-Euler map from two e-folds per step; real cascades need a time series of an oscillating discharge.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24202240
Primary Topic
Low-Pressure Plasma Processing and Diagnostics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Double probes and weak double layers share an exact recurrence but not their physics: log-frequency scales, presheath energetics and the limits of bifurcation overlays

Ahmed Hala
2 links
Zenodo (CERN European Organization for Nuclear Research)
Low-Pressure Plasma Processing and Diagnostics
preprint

Double probes and weak double layers share an exact recurrence but not their physics: log-frequency scales, presheath energetics and the limits of bifurcation overlays

Ahmed Hala
preprint en

Abstract

In log-odds the floating double-probe characteristic is an exact translation, and on any uniform bias grid it is an exact Beverton–Holt map. This paper works out what that exactness implies when bias is counted in nats (eV /Te), current as a share of the ion supply, and rates on a logarithmic axis. The multipliers of the map telescope to zero net expansion; an error in the starting value moves only the inferred floating point; and the probe’s response rate is u = u∗ + ln y(1 − y), so in the wings one e-fold of bias costs one e-fold of rate. A dwell schedule built on that ladder gives the same error per nat at every sample and a 4.6-fold shorter sweep for a typical probe. The factor 1 + GR both inflates the apparent temperature and divides the stable integration step, and a double probe in any passive circuit needs zero bits of feedback. Up–down residuals in log-odds separate capacitive current, contamination layers and drift by shape, with no fitted parameter. Read in nats, the presheath is an isothermal engine with efficiency η = 1/(2Φps), about 0.63 for a measured argon presheath. The sheath is a Boltzmann gate, and the only demon (a feedback element that senses a flux imbalance at the boundary and acts to correct it) that needs information is the friction that locks two ion species, which requires Φps ≥ 1 2 ⟨m⟩⟨1/m⟩: 1.51 nats for a balanced Ar–He mix. Archival thesis data on the Ar–He presheath instability are consistent with this cost if Te ≲ 3 eV. A weak double layer obeys the same recurrence as the double probe, but with a map parameter that scales with the layer’s drop rather than with Te. Finally, a logistic cascade overlaid on a trace or profile belongs to the forward-Euler map from two e-folds per step; real cascades need a time series of an oscillating discharge.

Zenodo (CERN European Organization for Nuclear Research)
Low-Pressure Plasma Processing and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon