Internal-energy regulation in grid-forming MMC-HVDC: A factorial study across weak-to-strong AC grids

Grid-forming (GFM) control of modular multilevel converters (MMCs) for HVDC links is governed by three coupled design choices: the inner AC loop (current control, CC, or direct voltage control, VC), the outer synchronization law (power-synchronization PI or virtual synchronous machine, VSM), and the inner energy loop (energy-based, EB, or non-energy-based, Non-EB). This paper evaluates these choices with a 2 × 2 × 2 × 5 factorial campaign: 40 active-power step scenarios and 72 large-disturbance cases covering low-voltage ride-through, bolted three-phase faults, and phase jumps over S C R = 1 –5. The simulations use an average-value MMC model that resolves arm-energy and circulating-current dynamics; it is validated in real time on an OPAL-RT OP5600 simulator against a switching-function model of the same converter, which it tracks to within 0 . 2 ms in rise time and 2 . 5 × 1 0 − 4 pu in steady state. The main result is that EB is required for large-disturbance energy containment within the tested framework: during a 1 5 0 ms, 0 . 3 pu voltage sag at ( C C , S C R = 1 . 3 ) , removing EB increases the stored-energy excursion from 1 . 0 6 % to 9 3 % , while EB keeps the excursion near 2 % across controller families and disturbances. The step campaign shows two additional effects. Under CC, the current loop masks the energy-loop choice on active-power overshoot ( < 0 . 2 percentage points, pp), supporting CC-PI as the simplest default when intrinsic current limitation is required. Under VC, the EB effect depends on the synchronization law: enabling EB raises VC-PI overshoot by 4 . 4 pp but reduces VC-VSM overshoot by 2 0 . 1 pp at S C R = 1 . These results condense into a compact, SCR-aware design map for selecting the inner loop, the synchronization law and the energy regulation of grid-forming MMC-HVDC converters.

Authors

Institutions

Publication Details

Journal
Next Energy
Published
2026-11-13
DOI
https://doi.org/10.1016/j.nxener.2026.101183
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Internal-energy regulation in grid-forming MMC-HVDC: A factorial study across weak-to-strong AC grids

Mohammed Abdeldjalil Djehaf, Anis Feddaoui
1 links
Next Energy
HVDC Systems and Fault Protection
article

Internal-energy regulation in grid-forming MMC-HVDC: A factorial study across weak-to-strong AC grids

Mohammed Abdeldjalil Djehaf, Anis Feddaoui
article en

Abstract

Grid-forming (GFM) control of modular multilevel converters (MMCs) for HVDC links is governed by three coupled design choices: the inner AC loop (current control, CC, or direct voltage control, VC), the outer synchronization law (power-synchronization PI or virtual synchronous machine, VSM), and the inner energy loop (energy-based, EB, or non-energy-based, Non-EB). This paper evaluates these choices with a 2 × 2 × 2 × 5 factorial campaign: 40 active-power step scenarios and 72 large-disturbance cases covering low-voltage ride-through, bolted three-phase faults, and phase jumps over S C R = 1 –5. The simulations use an average-value MMC model that resolves arm-energy and circulating-current dynamics; it is validated in real time on an OPAL-RT OP5600 simulator against a switching-function model of the same converter, which it tracks to within 0 . 2 ms in rise time and 2 . 5 × 1 0 − 4 pu in steady state. The main result is that EB is required for large-disturbance energy containment within the tested framework: during a 1 5 0 ms, 0 . 3 pu voltage sag at ( C C , S C R = 1 . 3 ) , removing EB increases the stored-energy excursion from 1 . 0 6 % to 9 3 % , while EB keeps the excursion near 2 % across controller families and disturbances. The step campaign shows two additional effects. Under CC, the current loop masks the energy-loop choice on active-power overshoot ( < 0 . 2 percentage points, pp), supporting CC-PI as the simplest default when intrinsic current limitation is required. Under VC, the EB effect depends on the synchronization law: enabling EB raises VC-PI overshoot by 4 . 4 pp but reduces VC-VSM overshoot by 2 0 . 1 pp at S C R = 1 . These results condense into a compact, SCR-aware design map for selecting the inner loop, the synchronization law and the energy regulation of grid-forming MMC-HVDC converters.

Next EnergyVol. 14
Badji Mokhtar-Annaba University (DZ), Université Djilali de Sidi Bel Abbès (DZ)
Affordable and clean energy, Industry, innovation and infrastructure
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon