MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia.

PURPOSE: Bonding to zirconia remains challenging because of its polycrystalline structure, and intraoperative blood contamination further compromises resin-zirconia adhesion. 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based cleaners have been proposed to restore bond strength to contaminated zirconia, but their mechanism and durability under aging remain incompletely characterized. This study evaluated the effect of an MDP-based cleaner on the shear bond strength (SBS) and chemical interaction of a self-adhesive resin cement bonded to clean and blood-contaminated zirconia. METHODS AND MATERIALS: Zirconia discs were air-abraded and allocated to four groups: clean zirconia without pretreatment; clean zirconia treated with MDP-cleaner; blood-contaminated zirconia without pretreatment; and blood-contaminated zirconia treated with MDP-cleaner. Self-adhesive resin cement was bonded to each surface. SBS was measured after 24-h water storage or 5,000 thermocycles (n = 15) and analyzed with three-way ANOVA and Tukey's test (α = 0.05). Surface morphology was evaluated by scanning electron microscopy (SEM), and chemical composition and cement-zirconia interaction were evaluated by X-ray photoelectron spectroscopy (XPS). RESULTS: Blood contamination significantly reduced 24-h SBS (p 0.001), decreasing further after thermocycling (p = 0.004). MDP-cleaner treatment recovered SBS on contaminated zirconia (p 0.001) and maintained stability after thermocycling (p = 0.12). SEM showed no morphological alterations. XPS showed partial reduction of nitrogen-containing blood proteins and a pattern consistent with chemical interactions between MDP-derived phosphate groups and zirconia. CONCLUSION: MDP-based cleaner restored bond strength of self-adhesive resin cement to blood-contaminated zirconia and maintained it after thermocycling. This was accompanied by partial reduction of blood-derived surface contamination and uptake of MDP-derived phosphate onto the zirconia surface, with negligible effect on clean zirconia.

Authors

Publication Details

Journal
PubMed
Published
2026-11-13
DOI
https://doi.org/10.3290/j.jad.c_2865
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia.

Pasiree Thongthai, Janeta Chavanavesh, Kittisak Sanon, J Tagami et al.
3 links
PubMed
Dental materials and restorations
article

MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia.

Pasiree Thongthai, Janeta Chavanavesh, Kittisak Sanon, J Tagami, Irin Chiwasuchin, Pharsiri Sirirangsee
article en

Abstract

PURPOSE: Bonding to zirconia remains challenging because of its polycrystalline structure, and intraoperative blood contamination further compromises resin-zirconia adhesion. 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based cleaners have been proposed to restore bond strength to contaminated zirconia, but their mechanism and durability under aging remain incompletely characterized. This study evaluated the effect of an MDP-based cleaner on the shear bond strength (SBS) and chemical interaction of a self-adhesive resin cement bonded to clean and blood-contaminated zirconia. METHODS AND MATERIALS: Zirconia discs were air-abraded and allocated to four groups: clean zirconia without pretreatment; clean zirconia treated with MDP-cleaner; blood-contaminated zirconia without pretreatment; and blood-contaminated zirconia treated with MDP-cleaner. Self-adhesive resin cement was bonded to each surface. SBS was measured after 24-h water storage or 5,000 thermocycles (n = 15) and analyzed with three-way ANOVA and Tukey's test (α = 0.05). Surface morphology was evaluated by scanning electron microscopy (SEM), and chemical composition and cement-zirconia interaction were evaluated by X-ray photoelectron spectroscopy (XPS). RESULTS: Blood contamination significantly reduced 24-h SBS (p 0.001), decreasing further after thermocycling (p = 0.004). MDP-cleaner treatment recovered SBS on contaminated zirconia (p 0.001) and maintained stability after thermocycling (p = 0.12). SEM showed no morphological alterations. XPS showed partial reduction of nitrogen-containing blood proteins and a pattern consistent with chemical interactions between MDP-derived phosphate groups and zirconia. CONCLUSION: MDP-based cleaner restored bond strength of self-adhesive resin cement to blood-contaminated zirconia and maintained it after thermocycling. This was accompanied by partial reduction of blood-derived surface contamination and uptake of MDP-derived phosphate onto the zirconia surface, with negligible effect on clean zirconia.

PubMedVol. 28
Good health and well-being
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon