Permeability Contrast Controls Inter-Layer Interference and Sweep Efficiency During Supercritical CO2 Miscible Flooding

Multi-layer combined development is widely adopted in low-to-medium-permeability sandstone reservoirs to balance economic efficiency and development performance during supercritical CO2 miscible flooding. However, permeability heterogeneity often induces severe inter-layer interference and gas channeling. To quantitatively clarify the dynamic influence of permeability heterogeneity on commingled injection and production systems, this study conducted single-core baseline tests (ranging from 19.17 mD to 205.60 mD) and three-core parallel physical simulation experiments at 150 °C and 50 MPa with varying permeability contrasts (nominal ratios of 5, 7, and 10; actual ratios of 5.15, 7.22, and 10.73, by fixing the medium- and low-permeability layers). The experimental results demonstrate that recovery increased with permeability across the tested assemblies, with single-core ultimate recovery increasing monotonically from 64.69% to 78.68% as permeability rises, accompanied by earlier CO2 breakthrough and lower peak pressure drops. In parallel combined development systems, permeability contrast serves as the dominant factor associated with inter-layer flow competition and dynamic shielding. At a high permeability contrast of 10, the high-permeability layer in the combination experiences premature gas breakthrough, with instantaneous split ratios generally between 60% and 85% (mean 71.63%) and consistent with substantial pressure relief. The observed zero recovery in the low-permeability layer is consistent with a dynamic shielding mechanism, in which early pressure relief in the high-permeability layer is interpreted as limiting the driving pressure drop available for low-permeability mobilization. As the permeability contrast decreases to 7 and 5, the flow resistance imbalance is significantly mitigated, allowing the low-permeability layer’s recovery factor to increase to 19.06% and 38.49%, respectively. At nominal ΔK = 5, this corresponds to a 26.20 percentage-point deficit and a 40.50% relative suppression compared with its single-core baseline (64.69%). Furthermore, system overall recovery improves substantially from 45.27% to 59.91%, and cumulative gas–oil ratios drop noticeably. The smallest tested permeability contrast gave the highest combined recovery under the experimental conditions. This is an experimentally observed case, not a general or calibrated threshold. The novelty of this work lies in providing a controlled-variable three-core parallel dataset under supercritical miscible conditions, providing macroscopic evidence interpreted as dynamic shielding of low-permeability layers, and identifying the smallest tested permeability contrast as a reference condition for optimized sweep efficiency. This study provides crucial physical simulation support and technical references for rational layer-combination division, stratified gas injection strategies, and subsequent mobility control optimization in heterogeneous reservoirs.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-13
DOI
https://doi.org/10.3390/en19225467
Primary Topic
Enhanced Oil Recovery Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Permeability Contrast Controls Inter-Layer Interference and Sweep Efficiency During Supercritical CO2 Miscible Flooding

S. Wang, Qingchun Meng, Zhenjie Wang, Lijian Li et al.
1 links
Energies
Enhanced Oil Recovery Techniques
article

Permeability Contrast Controls Inter-Layer Interference and Sweep Efficiency During Supercritical CO2 Miscible Flooding

S. Wang, Qingchun Meng, Zhenjie Wang, Lijian Li, Wenhao Li, Yu Sun
article en

Abstract

Multi-layer combined development is widely adopted in low-to-medium-permeability sandstone reservoirs to balance economic efficiency and development performance during supercritical CO2 miscible flooding. However, permeability heterogeneity often induces severe inter-layer interference and gas channeling. To quantitatively clarify the dynamic influence of permeability heterogeneity on commingled injection and production systems, this study conducted single-core baseline tests (ranging from 19.17 mD to 205.60 mD) and three-core parallel physical simulation experiments at 150 °C and 50 MPa with varying permeability contrasts (nominal ratios of 5, 7, and 10; actual ratios of 5.15, 7.22, and 10.73, by fixing the medium- and low-permeability layers). The experimental results demonstrate that recovery increased with permeability across the tested assemblies, with single-core ultimate recovery increasing monotonically from 64.69% to 78.68% as permeability rises, accompanied by earlier CO2 breakthrough and lower peak pressure drops. In parallel combined development systems, permeability contrast serves as the dominant factor associated with inter-layer flow competition and dynamic shielding. At a high permeability contrast of 10, the high-permeability layer in the combination experiences premature gas breakthrough, with instantaneous split ratios generally between 60% and 85% (mean 71.63%) and consistent with substantial pressure relief. The observed zero recovery in the low-permeability layer is consistent with a dynamic shielding mechanism, in which early pressure relief in the high-permeability layer is interpreted as limiting the driving pressure drop available for low-permeability mobilization. As the permeability contrast decreases to 7 and 5, the flow resistance imbalance is significantly mitigated, allowing the low-permeability layer’s recovery factor to increase to 19.06% and 38.49%, respectively. At nominal ΔK = 5, this corresponds to a 26.20 percentage-point deficit and a 40.50% relative suppression compared with its single-core baseline (64.69%). Furthermore, system overall recovery improves substantially from 45.27% to 59.91%, and cumulative gas–oil ratios drop noticeably. The smallest tested permeability contrast gave the highest combined recovery under the experimental conditions. This is an experimentally observed case, not a general or calibrated threshold. The novelty of this work lies in providing a controlled-variable three-core parallel dataset under supercritical miscible conditions, providing macroscopic evidence interpreted as dynamic shielding of low-permeability layers, and identifying the smallest tested permeability contrast as a reference condition for optimized sweep efficiency. This study provides crucial physical simulation support and technical references for rational layer-combination division, stratified gas injection strategies, and subsequent mobility control optimization in heterogeneous reservoirs.

EnergiesVol. 19(22)
China University of Petroleum, Beijing (CN), China National Petroleum Corporation (China) (CN)
National Science and Technology Major Project
Enhanced Oil Recovery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon