Improving Transmission Line Gap Insulation Performance Using Polyurea Coatings: An Experimental Study With Copper Rod Simulations of Bird Droppings

ABSTRACT Advancements in power systems and the rising demand for high power quality have heightened the focus on transmission line safety and stability to ensure safe and efficient energy system operation. However, high‐voltage transmission line towers are susceptible to bird‐related damage, leading to flashover faults and even power outages. This study adopts an experimental methodology, using copper rods as surrogates for bird droppings, to investigate the effectiveness of two‐component polyurea materials in improving the gap insulation performance under bird‐related conditions. Polyurea coatings were applied to the high‐ and ground‐potential sides in three different insulation configurations: insulation on both the high‐ and ground‐potential sides, insulation only on the high‐potential side, and insulation only on the ground‐potential side. Electric‐field distribution simulations and alternating current breakdown tests revealed that, compared with the configuration without local insulation, those with polyurea coatings optimise the electric‐field distribution, enhance the insulation reliability, widen the gap's safety margin and increase the breakdown voltage. Among the tested configurations, the one with polyurea coatings on the high‐ and ground‐potential sides demonstrated the best insulation performance, substantially increasing gap breakdown voltage. These experimental findings confirm the reliability of polyurea materials in improving transmission line insulation, offering new insights and an experimental foundation for further research aimed at enhancing insulation reliability and safety in transmission systems.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2026-11-13
DOI
https://doi.org/10.1049/hve2.70251
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Improving Transmission Line Gap Insulation Performance Using Polyurea Coatings: An Experimental Study With Copper Rod Simulations of Bird Droppings

Haishun Zhang, Songsong Zhou, Liang Jinxiang, Hechen Liu et al.
2 links
High Voltage
High voltage insulation and dielectric phenomena
article

Improving Transmission Line Gap Insulation Performance Using Polyurea Coatings: An Experimental Study With Copper Rod Simulations of Bird Droppings

Haishun Zhang, Songsong Zhou, Liang Jinxiang, Hechen Liu, Li Tang, Le Li, Huajie Shen, Yifan Liu, Wenhua Wu, Yunpeng Liu, Zhongyuan Zhang
article en

Abstract

ABSTRACT Advancements in power systems and the rising demand for high power quality have heightened the focus on transmission line safety and stability to ensure safe and efficient energy system operation. However, high‐voltage transmission line towers are susceptible to bird‐related damage, leading to flashover faults and even power outages. This study adopts an experimental methodology, using copper rods as surrogates for bird droppings, to investigate the effectiveness of two‐component polyurea materials in improving the gap insulation performance under bird‐related conditions. Polyurea coatings were applied to the high‐ and ground‐potential sides in three different insulation configurations: insulation on both the high‐ and ground‐potential sides, insulation only on the high‐potential side, and insulation only on the ground‐potential side. Electric‐field distribution simulations and alternating current breakdown tests revealed that, compared with the configuration without local insulation, those with polyurea coatings optimise the electric‐field distribution, enhance the insulation reliability, widen the gap's safety margin and increase the breakdown voltage. Among the tested configurations, the one with polyurea coatings on the high‐ and ground‐potential sides demonstrated the best insulation performance, substantially increasing gap breakdown voltage. These experimental findings confirm the reliability of polyurea materials in improving transmission line insulation, offering new insights and an experimental foundation for further research aimed at enhancing insulation reliability and safety in transmission systems.

High Voltage
North China Electric Power University (CN), China Electric Power Research Institute (CN), China Southern Power Grid (China) (CN)
State Grid Corporation of China, Science and Technology Project of State Grid
Industry, innovation and infrastructure
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon