Late Fluorescence Goes First: Dose-Resolved Suppression in Time-Gated Raman Spectroscopy of Recycled Poly(ethylene terephthalate)

The fluorescence of recycled poly(ethylene terephthalate) (rPET) was followed at two fixed spots with a time-gated Raman spectrometer (532 nm, 150 ps, 150 kHz), with the dose counted in laser pulses. At one spot, with the pile-up correction applied by the instrument software, the mean of the last three spectra, after 8.86 × 10 7 pulses, retained 0.208 ± 0.008 of the time-integrated fluorescence of the first run and 0.243 ± 0.009 of the gated fluorescence, and the Raman-to-fluorescence ratio increased by a factor of 5.52 ± 0.21 in the time-integrated data but by 4.87 ± 0.19 in the gated data. At a second spot, with a lower count rate, the fraction of the fluorescence inside the gate increased by a factor of 1.077 ± 0.011 with the correction and 1.043 ± 0.006 without it. Time-correlated single photon counting resolves the fluorescence decay within each acquisition: the late component is lost first. The Raman spectrum was preserved: all bands changed by a common factor. After pauses in illumination, the fluorescence was partly restored, by (2.4 ± 1.0)% per 100 s. This loss is consistent with the irreversible branch of the optical depletion proposed for solutions by Hamaguchi, Tahara, and Tasumi (Appl. Spectrosc. 1987. 41(8): 1265–1268).

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-12
DOI
https://doi.org/10.26434/chemrxiv.15012088/v1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Late Fluorescence Goes First: Dose-Resolved Suppression in Time-Gated Raman Spectroscopy of Recycled Poly(ethylene terephthalate)

Nicolás Spegazzini
ChemRxiv
Spectroscopy Techniques in Biomedical and Chemical Research
preprint

Late Fluorescence Goes First: Dose-Resolved Suppression in Time-Gated Raman Spectroscopy of Recycled Poly(ethylene terephthalate)

Nicolás Spegazzini
preprint en

Abstract

The fluorescence of recycled poly(ethylene terephthalate) (rPET) was followed at two fixed spots with a time-gated Raman spectrometer (532 nm, 150 ps, 150 kHz), with the dose counted in laser pulses. At one spot, with the pile-up correction applied by the instrument software, the mean of the last three spectra, after 8.86 × 10 7 pulses, retained 0.208 ± 0.008 of the time-integrated fluorescence of the first run and 0.243 ± 0.009 of the gated fluorescence, and the Raman-to-fluorescence ratio increased by a factor of 5.52 ± 0.21 in the time-integrated data but by 4.87 ± 0.19 in the gated data. At a second spot, with a lower count rate, the fraction of the fluorescence inside the gate increased by a factor of 1.077 ± 0.011 with the correction and 1.043 ± 0.006 without it. Time-correlated single photon counting resolves the fluorescence decay within each acquisition: the late component is lost first. The Raman spectrum was preserved: all bands changed by a common factor. After pauses in illumination, the fluorescence was partly restored, by (2.4 ± 1.0)% per 100 s. This loss is consistent with the irreversible branch of the optical depletion proposed for solutions by Hamaguchi, Tahara, and Tasumi (Appl. Spectrosc. 1987. 41(8): 1265–1268).

ChemRxiv
VTT Technical Research Centre of Finland (FI)
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon