Circular Polarisation as a Discriminant: Why a Pure Rotation Generates No Stokes V

This paper examines whether mechanisms proposed to explain a polarisation rotation can be distinguished by their effect on circular polarisation, and what limit a non-detection of Stokes V places on mechanisms that mix linear and circular states. The calculation is performed from stated assumptions and published polarisation measurements, using the deposited script so that every quoted number can be reproduced. The headline outputs are: rotated U uK = 0.0314; V generated uK = 0.000; V limit pct of Q = 1.0; admixture bound pct = 1.0. The treatment separates what the published measurements supply from what a theoretical framework must additionally provide; where a required quantity is not supplied, that absence is reported plainly as a negative result rather than replaced by an assumed value. The study is computed from stated assumptions and published inputs; it is not a new measurement. SIMULATED, NOT MEASURED in the sense that all derived quantities are calculated, not observed.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24168749
Primary Topic
Stellar, planetary, and galactic studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Circular Polarisation as a Discriminant: Why a Pure Rotation Generates No Stokes V

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Stellar, planetary, and galactic studies
article

Circular Polarisation as a Discriminant: Why a Pure Rotation Generates No Stokes V

William Alexander Aldred
article en

Abstract

This paper examines whether mechanisms proposed to explain a polarisation rotation can be distinguished by their effect on circular polarisation, and what limit a non-detection of Stokes V places on mechanisms that mix linear and circular states. The calculation is performed from stated assumptions and published polarisation measurements, using the deposited script so that every quoted number can be reproduced. The headline outputs are: rotated U uK = 0.0314; V generated uK = 0.000; V limit pct of Q = 1.0; admixture bound pct = 1.0. The treatment separates what the published measurements supply from what a theoretical framework must additionally provide; where a required quantity is not supplied, that absence is reported plainly as a negative result rather than replaced by an assumed value. The study is computed from stated assumptions and published inputs; it is not a new measurement. SIMULATED, NOT MEASURED in the sense that all derived quantities are calculated, not observed.

Zenodo (CERN European Organization for Nuclear Research)
Stellar, planetary, and galactic studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon