Time and Accuracy of Manual Protected Health Information Redaction in Biospecimen and Clinical Research Workflows: An Exploratory Pilot Benchmark Against Automation

BACKGROUND: Clinical research and biobanking workflows require retrieval and redaction of protected health information (PHI) from clinical documents before sharing with sponsors and investigators, often alongside biospecimens. Manual redaction is time-intensive, error-prone, and may increase organizational risk through privacy exposure. Automated redaction tools could reduce human burden, improve completeness, and minimize exposure. OBJECTIVE: This exploratory pilot study aimed to measure the human time burden of manual document retrieval and PHI redaction across common clinical document types, quantify accuracy based on missed PHI (false-negative) patterns, and benchmark results against a fully automated redaction system applied to the same source documents. METHODS: A prospective time-motion and error characterization study with six experienced research staff were performed. Each participant redacted nine documents four discharge reports, four pathology reports, and one lab-results report. Automated time was defined as zero human time, as machine runtime does not represent human effort; missed PHI was measured using the same criteria in both conditions. RESULTS: Six participants each completed nine documents (54 total). Mean manual session time was 058:54. Mean document-level time was ∼0:06:05, excluding Research Electronic Data Capture search (0:00:51) and miscellaneous time (0:00:48). Manual redaction produced 55 missed PHI instances (∼1.02/document); the automated system missed 3 instances across 18 unique documents (∼0.17/document), all medical staff names. CONCLUSION: Automated redaction was associated with fewer missed PHI instances with no measurable human time burden. These exploratory results suggest automation may reduce privacy risk and eliminate the nonredaction workflow steps comprising nearly 40% of manual session time, supporting further evaluation in biospecimen research and biobanking operations.

Authors

Institutions

Publication Details

Journal
Biopreservation and Biobanking
Published
2026-11-12
DOI
https://doi.org/10.1177/19475535261506195
Primary Topic
Electronic Health Records Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Time and Accuracy of Manual Protected Health Information Redaction in Biospecimen and Clinical Research Workflows: An Exploratory Pilot Benchmark Against Automation

Yonah C. Ziemba, Cristina Valente, Faraz Yousuf, Isabella Travaglia et al.
Biopreservation and Biobanking
Electronic Health Records Systems
article

Time and Accuracy of Manual Protected Health Information Redaction in Biospecimen and Clinical Research Workflows: An Exploratory Pilot Benchmark Against Automation

Yonah C. Ziemba, Cristina Valente, Faraz Yousuf, Isabella Travaglia, Michelle LoGuercio, Sharon Fox, Christopher Familusi, Kimberly Jimenez, Briana Zhang, Kritzia Nunez
article en

Abstract

BACKGROUND: Clinical research and biobanking workflows require retrieval and redaction of protected health information (PHI) from clinical documents before sharing with sponsors and investigators, often alongside biospecimens. Manual redaction is time-intensive, error-prone, and may increase organizational risk through privacy exposure. Automated redaction tools could reduce human burden, improve completeness, and minimize exposure. OBJECTIVE: This exploratory pilot study aimed to measure the human time burden of manual document retrieval and PHI redaction across common clinical document types, quantify accuracy based on missed PHI (false-negative) patterns, and benchmark results against a fully automated redaction system applied to the same source documents. METHODS: A prospective time-motion and error characterization study with six experienced research staff were performed. Each participant redacted nine documents four discharge reports, four pathology reports, and one lab-results report. Automated time was defined as zero human time, as machine runtime does not represent human effort; missed PHI was measured using the same criteria in both conditions. RESULTS: Six participants each completed nine documents (54 total). Mean manual session time was 058:54. Mean document-level time was ∼0:06:05, excluding Research Electronic Data Capture search (0:00:51) and miscellaneous time (0:00:48). Manual redaction produced 55 missed PHI instances (∼1.02/document); the automated system missed 3 instances across 18 unique documents (∼0.17/document), all medical staff names. CONCLUSION: Automated redaction was associated with fewer missed PHI instances with no measurable human time burden. These exploratory results suggest automation may reduce privacy risk and eliminate the nonredaction workflow steps comprising nearly 40% of manual session time, supporting further evaluation in biospecimen research and biobanking operations.

Biopreservation and Biobanking
Northwell Health (US)
Good health and well-being
Electronic Health Records Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon