Effect of ambient temperature on bioimpedance from a wearable sensor patch
Wearable bioimpedance sensors are promising tools for long-term home monitoring, but their measurements may be affected by ambient temperature and anatomical site. This study examined how cold and warm exposure influence local skin impedance measured by a miniaturized patch at four body locations.Twelve healthy volunteers (4 female, 8 male; 18-40 years) wore four Re:Balans ® Insight patches (upper back, upper arm, thigh, lower leg) for approximately 30 h. On two consecutive days, each participant underwent 1 h of exposure to either a cold (4 °C) or warm (37 °C) climate chamber in counterbalanced order, with preand post-exposure baseline periods. Multi-frequency bioimpedance (24 frequencies, 5.8-504 kHz) and skin temperature were recorded continuously and aligned to the 1 h climate chamber period. Two representative frequencies (7.4 kHz, 403.4 kHz) were analyzed for relative impedance change, time trends, and temperature sensitivity ∆Z/∆T . Non-parametric tests were used to compare locations and conditions.Cold exposure decreased skin temperature by about -3.2 to -5.2 • C and increased impedance at all sites, whereas warm exposure increased skin temperature by about +1.6 to +2.4 • C and decreased impedance at all sites. Relative and absolute changes were larger at 7.4 kHz than at 403.4 kHz. Location-dependent differences were small during cold exposure but more pronounced during warm exposure, with a moderate-to-large effect between upper back and lower leg that did not remain statistically significant after multiple comparison correction. All sites showed negative temperature sensitivity; limb locations exhibited higher |∆Z/∆T | and stronger impedance-temperature linearity than the upper back.Local skin impedance measured by wearable patches is sensitive to changes in ambient temperature in a frequency-and site-dependent manner. Extremity sites appear suitable for temperature-or blood-flow-related applications, whereas the upper back may be advantageous where temperature-induced variability should be minimized.
Authors
- Ole Elvebakk (ORCID: https://orcid.org/0000-0002-6779-1738)
- Jie Hou (ORCID: https://orcid.org/0000-0002-5765-1395)
- Sisay Mebre Abie
- Ørjan G. Martinsen (ORCID: https://orcid.org/0000-0003-1632-4352)
- Håvard Kalvøy (ORCID: https://orcid.org/0000-0001-8920-6555)
Institutions
- Oslo University Hospital (NO)
- University of Oslo (NO)
Publication Details
- Journal
- Medical Engineering & Physics
- Published
- 2026-11-12
- DOI
- https://doi.org/10.1088/1873-4030/aec16c
- Primary Topic
- Electrical and Bioimpedance Tomography
- Type
- article
- Field-Weighted Citation Impact
- 0.00