Patient-Specific AI-Guided Robotic Intraoral Scanning Using Deep Learning Residual Trajectory Control for the Dentatron Dental Robot

Accurate trajectory tracking is essential for autonomous dental scanning in the presence of patient-specific anatomical variations and robotic nonidealities. This study proposes a patient-specific trajectory-tracking framework for the four-DOF Dentatron dental robot using a deep learning residual controller. Ten patient-specific maxillary geometries were extracted and parameterized from upper-jaw intraoral scans obtained from the publicly available Teeth3DS+ dataset. The selected cases represented variations in intercanine width, intermolar width, total arch length, palatal depth, arch form, crowding, spacing, and asymmetry. Sixteen scanning targets were defined for each patient-derived geometry and converted into smooth Cartesian trajectories sampled at 100 Hz, resulting in a dataset of 31,000 trajectory samples. A MATLAB/Simulink–Simscape model of the Dentatron was developed incorporating representative robotic and sensing nonidealities, including joint dynamics, mechanical backlash, an 80 ms command delay, disturbances, encoder quantization, measurement noise, and sensor bias. The residual controller estimates joint-position and joint-speed corrections using patient-specific geometric descriptors, trajectory variables, and robot-state information. Patient-wise partitioning was employed to evaluate generalization to complete maxillary geometries excluded from model training. On the unseen test set, the overall joint-position RMSE decreased from approximately 0.34° to 0.26°, corresponding to a 22.7% improvement, while joint-speed RMSE decreased from approximately 1.25°/s to 0.96°/s, representing a 23.0% improvement. The strongest compensation was observed for joints with the largest baseline tracking errors, particularly J2 and J3, whereas smaller improvements were obtained for joints with lower initial errors. All generated patient-specific trajectories remained outside the adopted singularity region. These results demonstrate the feasibility of residual deep learning for improving patient-specific Dentatron trajectory tracking under simulated robotic nonidealities while maintaining kinematic feasibility.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2026-11-12
DOI
https://doi.org/10.3390/biomimetics11110827
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Patient-Specific AI-Guided Robotic Intraoral Scanning Using Deep Learning Residual Trajectory Control for the Dentatron Dental Robot

Amr Ahmed Azhari, Mohamed Fawzy El-Khatib, A. Abdellatif, Walaa Magdy Ahmed et al.
Biomimetics
Robotic Mechanisms and Dynamics
article

Patient-Specific AI-Guided Robotic Intraoral Scanning Using Deep Learning Residual Trajectory Control for the Dentatron Dental Robot

Amr Ahmed Azhari, Mohamed Fawzy El-Khatib, A. Abdellatif, Walaa Magdy Ahmed, Mostafa R. A. Atia, Magdy M. Hamdy, Muhammad A. Bakr
article en

Abstract

Accurate trajectory tracking is essential for autonomous dental scanning in the presence of patient-specific anatomical variations and robotic nonidealities. This study proposes a patient-specific trajectory-tracking framework for the four-DOF Dentatron dental robot using a deep learning residual controller. Ten patient-specific maxillary geometries were extracted and parameterized from upper-jaw intraoral scans obtained from the publicly available Teeth3DS+ dataset. The selected cases represented variations in intercanine width, intermolar width, total arch length, palatal depth, arch form, crowding, spacing, and asymmetry. Sixteen scanning targets were defined for each patient-derived geometry and converted into smooth Cartesian trajectories sampled at 100 Hz, resulting in a dataset of 31,000 trajectory samples. A MATLAB/Simulink–Simscape model of the Dentatron was developed incorporating representative robotic and sensing nonidealities, including joint dynamics, mechanical backlash, an 80 ms command delay, disturbances, encoder quantization, measurement noise, and sensor bias. The residual controller estimates joint-position and joint-speed corrections using patient-specific geometric descriptors, trajectory variables, and robot-state information. Patient-wise partitioning was employed to evaluate generalization to complete maxillary geometries excluded from model training. On the unseen test set, the overall joint-position RMSE decreased from approximately 0.34° to 0.26°, corresponding to a 22.7% improvement, while joint-speed RMSE decreased from approximately 1.25°/s to 0.96°/s, representing a 23.0% improvement. The strongest compensation was observed for joints with the largest baseline tracking errors, particularly J2 and J3, whereas smaller improvements were obtained for joints with lower initial errors. All generated patient-specific trajectories remained outside the adopted singularity region. These results demonstrate the feasibility of residual deep learning for improving patient-specific Dentatron trajectory tracking under simulated robotic nonidealities while maintaining kinematic feasibility.

BiomimeticsVol. 11(11)
King Abdulaziz University (SA), Arab Academy for Science, Technology, and Maritime Transport (EG), Egyptian Russian University (EG)
King Abdulaziz University
Good health and well-being
Robotic Mechanisms and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon