The Miscalibration Degeneracy: Instrument Angle Error, Foreground Self-Calibration, and the Reported Rotation

This paper examines how an error in the assumed orientation of a polarisation detector enters the measured rotation, why it is exactly degenerate with a uniform cosmic angle at map level, and what the common practice of self-calibrating on foregrounds does to the quantity that remains. The calculation is performed from stated assumptions and published polarisation measurements, using the deposited script so that every quoted number can be reproduced. The headline outputs are: true deg = 0.30; bias at alpha0p3 = 0.30; observed at alpha0p3 = 0.60; degeneracy = exact at map level for a uniform angle. The treatment separates what the published measurements supply from what a theoretical framework must additionally provide; where a required quantity is not supplied, that absence is reported plainly as a negative result rather than replaced by an assumed value. The study is computed from stated assumptions and published inputs; it is not a new measurement. SIMULATED, NOT MEASURED in the sense that all derived quantities are calculated, not observed.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24168851
Primary Topic
Cosmology and Gravitation Theories
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Miscalibration Degeneracy: Instrument Angle Error, Foreground Self-Calibration, and the Reported Rotation

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
article

The Miscalibration Degeneracy: Instrument Angle Error, Foreground Self-Calibration, and the Reported Rotation

William Alexander Aldred
article en

Abstract

This paper examines how an error in the assumed orientation of a polarisation detector enters the measured rotation, why it is exactly degenerate with a uniform cosmic angle at map level, and what the common practice of self-calibrating on foregrounds does to the quantity that remains. The calculation is performed from stated assumptions and published polarisation measurements, using the deposited script so that every quoted number can be reproduced. The headline outputs are: true deg = 0.30; bias at alpha0p3 = 0.30; observed at alpha0p3 = 0.60; degeneracy = exact at map level for a uniform angle. The treatment separates what the published measurements supply from what a theoretical framework must additionally provide; where a required quantity is not supplied, that absence is reported plainly as a negative result rather than replaced by an assumed value. The study is computed from stated assumptions and published inputs; it is not a new measurement. SIMULATED, NOT MEASURED in the sense that all derived quantities are calculated, not observed.

Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon