Thermal modeling of a rotary heat pump: effects of key parameters on performance

Abstract This study presents a transient thermal analysis of a rotary electrocaloric (EC) heat pump in which fluids circulate through channels bounded by electrocaloric material. The transient conjugate heat transfer problem is solved using both a finite-element model and a reduced-order analytical model. The reduced-order model predicts the cooling capacity with an average deviation of 8.08% from the finite-element solution while requiring significantly lower computational effort. Under the baseline operating conditions, the heat pump delivers a cooling capacity of 23.33 W, a coefficient of performance (COP) that includes electrical and mechanical power requirements of 22.827 and a relative Carnot efficiency of 7.79%. The analysis reveals the existence of a reverse heat pumping zone at the beginning of each heating and cooling stage, caused by the displacement of fluid transported from the previous stage, which reduces the net cooling capacity. Parametric calculations show that this reverse heat pumping effect becomes more pronounced at lower rotational speeds, lower fluid velocities, longer channel lengths, and larger temperature differences between the hot and cold reservoirs, ultimately limiting the operating range of the device. A conceptual tandem configuration employing alternating fluid inlets and inter-stage recirculation is proposed as a potential approach for increasing the achievable temperature span of a four-stage rotary electrocaloric heat pump to $$4.8349^{\circ}\textrm{C}$$ and the relative Carnot efficiency to 38.16%.

Authors

Institutions

Publication Details

Journal
International Journal of Air-Conditioning and Refrigeration
Published
2026-11-12
DOI
https://doi.org/10.1007/s44189-026-00122-5
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thermal modeling of a rotary heat pump: effects of key parameters on performance

Francisco Gerardo Pérez-Gutiérrez, Mihir Sen, Ricardo Romero‐Méndez
International Journal of Air-Conditioning and Refrigeration
Refrigeration and Air Conditioning Technologies
article

Thermal modeling of a rotary heat pump: effects of key parameters on performance

Francisco Gerardo Pérez-Gutiérrez, Mihir Sen, Ricardo Romero‐Méndez
article en

Abstract

Abstract This study presents a transient thermal analysis of a rotary electrocaloric (EC) heat pump in which fluids circulate through channels bounded by electrocaloric material. The transient conjugate heat transfer problem is solved using both a finite-element model and a reduced-order analytical model. The reduced-order model predicts the cooling capacity with an average deviation of 8.08% from the finite-element solution while requiring significantly lower computational effort. Under the baseline operating conditions, the heat pump delivers a cooling capacity of 23.33 W, a coefficient of performance (COP) that includes electrical and mechanical power requirements of 22.827 and a relative Carnot efficiency of 7.79%. The analysis reveals the existence of a reverse heat pumping zone at the beginning of each heating and cooling stage, caused by the displacement of fluid transported from the previous stage, which reduces the net cooling capacity. Parametric calculations show that this reverse heat pumping effect becomes more pronounced at lower rotational speeds, lower fluid velocities, longer channel lengths, and larger temperature differences between the hot and cold reservoirs, ultimately limiting the operating range of the device. A conceptual tandem configuration employing alternating fluid inlets and inter-stage recirculation is proposed as a potential approach for increasing the achievable temperature span of a four-stage rotary electrocaloric heat pump to $$4.8349^{\circ}\textrm{C}$$ and the relative Carnot efficiency to 38.16%.

International Journal of Air-Conditioning and RefrigerationVol. 34(1)
University of Notre Dame (US), Autonomous University of San Luis Potosí (MX)
Affordable and clean energy
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon