Enhanced Temperature Sensitivity by Nickel–Copper-Coated Optical Fiber in Distributed Sensing Based on Rayleigh Scattering

In this paper, the temperature and relative humidity (RH) response of a nickel–copper-coated (Ni-Cu-coated) optical fiber was investigated using a Rayleigh-based optical frequency-domain reflectometer (OFDR). The temperature sensitivity of the Ni-Cu-coated optical fiber was determined experimentally as −2.50 GHz/°C, which is significantly higher than that of standard single-mode optical fibers. Measurements performed under controlled RH conditions reveal that the Ni-Cu-coated optical fiber has negligible response to RH. The Ni-Cu-coated optical fiber could be used for distributed temperature sensing in Rayleigh-based OFDR setups with high spatial resolution in environments with varying RH conditions.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-12
DOI
https://doi.org/10.3390/s26227148
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhanced Temperature Sensitivity by Nickel–Copper-Coated Optical Fiber in Distributed Sensing Based on Rayleigh Scattering

Bogusław Szczupak, Mateusz Mądry, Daniel Lis, Katarzyna Garbacz
Sensors
Advanced Fiber Optic Sensors
article

Enhanced Temperature Sensitivity by Nickel–Copper-Coated Optical Fiber in Distributed Sensing Based on Rayleigh Scattering

Bogusław Szczupak, Mateusz Mądry, Daniel Lis, Katarzyna Garbacz
article en

Abstract

In this paper, the temperature and relative humidity (RH) response of a nickel–copper-coated (Ni-Cu-coated) optical fiber was investigated using a Rayleigh-based optical frequency-domain reflectometer (OFDR). The temperature sensitivity of the Ni-Cu-coated optical fiber was determined experimentally as −2.50 GHz/°C, which is significantly higher than that of standard single-mode optical fibers. Measurements performed under controlled RH conditions reveal that the Ni-Cu-coated optical fiber has negligible response to RH. The Ni-Cu-coated optical fiber could be used for distributed temperature sensing in Rayleigh-based OFDR setups with high spatial resolution in environments with varying RH conditions.

SensorsVol. 26(22)
Wrocław University of Science and Technology (PL), AGH University of Krakow (PL)
Politechnika Wrocławska
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon