Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador

The electricity supply in rural communities of Ecuador faces limitations due to the strong dependence on hydropower sources and the lack of alternative backup systems. Photovoltaic systems with automated solar tracking mechanisms emerge as a viable alternative to optimize energy harvesting and enhance energy security. This study aims to design, implement, and validate a 200 Wp photovoltaic generator equipped with a 2000 W inverter with 100 Ah battery backup, integrating a two-axis automated solar tracking mechanism and a remote control interface accessible through mobile devices. The methodology included system sizing using the Photovoltaic Geographical Information System (PVGIS), structural modeling in Autodesk Inventor Professional, implementation of a control system based on an Arduino Mega 2560 with current, voltage, and temperature sensors, and the development of a remote monitoring interface using the RemoteXY platform. Experimental results showed that the tracking mechanism maintained the perpendicular orientation of the solar panels relative to incident radiation, achieving ranges of 137° in elevation and 47° in declination. Automatic switching through the ATS device was successfully verified without observable interruptions of the connected load. According to the manufacturer specifications, the ATS transfer time is below 50 ms, although this value was not independently measured during the experimental validation. Stable access to the remote interface was also achieved, with an external network connection success rate of 93.33%. The failure rate under low-radiation conditions was approximately 17%. The system represents a significant technological contribution for rural areas with limited access to reliable electricity, and establishes the basis for future improvements in control algorithms and sensor sensitivity for solar tracking systems.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-12
DOI
https://doi.org/10.3390/en19225439
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador

René Cortijo, Henry Díaz, Marco Vivero Tenorio
Energies
Photovoltaic System Optimization Techniques
article

Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador

René Cortijo, Henry Díaz, Marco Vivero Tenorio
article en

Abstract

The electricity supply in rural communities of Ecuador faces limitations due to the strong dependence on hydropower sources and the lack of alternative backup systems. Photovoltaic systems with automated solar tracking mechanisms emerge as a viable alternative to optimize energy harvesting and enhance energy security. This study aims to design, implement, and validate a 200 Wp photovoltaic generator equipped with a 2000 W inverter with 100 Ah battery backup, integrating a two-axis automated solar tracking mechanism and a remote control interface accessible through mobile devices. The methodology included system sizing using the Photovoltaic Geographical Information System (PVGIS), structural modeling in Autodesk Inventor Professional, implementation of a control system based on an Arduino Mega 2560 with current, voltage, and temperature sensors, and the development of a remote monitoring interface using the RemoteXY platform. Experimental results showed that the tracking mechanism maintained the perpendicular orientation of the solar panels relative to incident radiation, achieving ranges of 137° in elevation and 47° in declination. Automatic switching through the ATS device was successfully verified without observable interruptions of the connected load. According to the manufacturer specifications, the ATS transfer time is below 50 ms, although this value was not independently measured during the experimental validation. Stable access to the remote interface was also achieved, with an external network connection success rate of 93.33%. The failure rate under low-radiation conditions was approximately 17%. The system represents a significant technological contribution for rural areas with limited access to reliable electricity, and establishes the basis for future improvements in control algorithms and sensor sensitivity for solar tracking systems.

EnergiesVol. 19(22)
Universidad de las Fuerzas Armadas ESPE (EC), Universidad Israel (EC)
Industry, innovation and infrastructure, Affordable and clean energy, Climate action
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon