Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection

Esophageal squamous cell carcinoma (ESCC) is one of the most aggressive malignancies of the digestive tract, making early detection critically important for improving patient survival and treatment outcomes. Biomarker detection is routinely employed as one of the primary modalities for the identification of ESCC. Despite advantages of high sensitivity and fast response, current optical fiber biosensors still face the main challenges of multi-biomarker detection to reduce false-positive results and compensation of the interference from bulk refractive index (BRI) variations for reliable measurement. Here, we report a distributed fiber-optic biosensor capable of simultaneously detecting ESCC dual biomarkers with BRI self-compensation. A step-tapered fiber (STF) sensor is designed with two distinct tapered regions for biomarker detection with BRI compensation. Optical frequency domain reflectometry is employed to simultaneously interrogate the two regions, enabling accurate and rapid detection of ESCC dual biomarkers in a single-shot distributed measurement. Simultaneous detection of both Cyfra21-1 and squamous cell carcinoma antigen (SCCA) biomarkers has been demonstrated within a short assay time of less than 30 min and with an average relative error of 13.8 and 15%, respectively, showing 4.5 times and 11.5 times accuracy improvement when compared to those without BRI compensation. Limits of detection of 0.07 and 0.1 ng/mL have been achieved for Cyfra21-1 and SCCA detection, respectively. The capability of multi-biomarker detection with BRI self-compensation would greatly reduce false-positive rates in ESCC diagnosis.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-11-12
DOI
https://doi.org/10.1021/acssensors.6c03378
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection

Liang Wang, KAN Xuefeng, Zitao Wang, Zihang Ji et al.
ACS Sensors
Advanced Fiber Optic Sensors
article

Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection

Liang Wang, KAN Xuefeng, Zitao Wang, Zihang Ji, Zhou Xu, Yikai Wu, Wei Ping, Lei Tu, Tianle Chen, Lisong Yan, Zhenjie Lu, Ming Tang
article en

Abstract

Esophageal squamous cell carcinoma (ESCC) is one of the most aggressive malignancies of the digestive tract, making early detection critically important for improving patient survival and treatment outcomes. Biomarker detection is routinely employed as one of the primary modalities for the identification of ESCC. Despite advantages of high sensitivity and fast response, current optical fiber biosensors still face the main challenges of multi-biomarker detection to reduce false-positive results and compensation of the interference from bulk refractive index (BRI) variations for reliable measurement. Here, we report a distributed fiber-optic biosensor capable of simultaneously detecting ESCC dual biomarkers with BRI self-compensation. A step-tapered fiber (STF) sensor is designed with two distinct tapered regions for biomarker detection with BRI compensation. Optical frequency domain reflectometry is employed to simultaneously interrogate the two regions, enabling accurate and rapid detection of ESCC dual biomarkers in a single-shot distributed measurement. Simultaneous detection of both Cyfra21-1 and squamous cell carcinoma antigen (SCCA) biomarkers has been demonstrated within a short assay time of less than 30 min and with an average relative error of 13.8 and 15%, respectively, showing 4.5 times and 11.5 times accuracy improvement when compared to those without BRI compensation. Limits of detection of 0.07 and 0.1 ng/mL have been achieved for Cyfra21-1 and SCCA detection, respectively. The capability of multi-biomarker detection with BRI self-compensation would greatly reduce false-positive rates in ESCC diagnosis.

ACS Sensors
Tongji Hospital (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, Huazhong University of Science and Technology
Good health and well-being
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon