Microdose CT for postlung biopsy pneumothorax detection: A case series

Pneumothorax is the most common complication of computed tomography (CT)-guided percutaneous transthoracic biopsy, an important diagnostic procedure in the workup of pulmonary nodules. Timely and accurate detection of pneumothorax postlung biopsy can guide management and prevent further morbidity. We present 3 cases comparing chest radiography (CXR) with microdose CT for detecting postlung biopsy pneumothorax. In each case, microdose CT resulted in diagnostically sufficient images with effective dose ranges of 0.0417-0.0538 mSv, corresponding to an effective dose range of approximately 2.5 CXRs. In case 3, a small loculated pneumothorax not readily apparent on CXR was more easily appreciated on microdose CT. This case series highlights a novel real-world clinical application of microdose CT for postbiopsy pneumothorax detection which has not been well documented previously that warrants prospective evaluation. Studies are needed to assess microdose CT diagnostic accuracy, feasibility, and clinical impact when used in a postbiopsy procedural setting.

Authors

Institutions

Publication Details

Journal
Radiology Case Reports
Published
2026-11-12
DOI
https://doi.org/10.1016/j.radcr.2026.10.033
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Microdose CT for postlung biopsy pneumothorax detection: A case series

Nadeem Almalki, Abdulrahman Al Bochi, Youssef Almalki, Bader Abou Shaar et al.
Radiology Case Reports
Radiation Dose and Imaging
article

Microdose CT for postlung biopsy pneumothorax detection: A case series

Nadeem Almalki, Abdulrahman Al Bochi, Youssef Almalki, Bader Abou Shaar, Sohaib Munir, Zayd Alkassem
article en

Abstract

Pneumothorax is the most common complication of computed tomography (CT)-guided percutaneous transthoracic biopsy, an important diagnostic procedure in the workup of pulmonary nodules. Timely and accurate detection of pneumothorax postlung biopsy can guide management and prevent further morbidity. We present 3 cases comparing chest radiography (CXR) with microdose CT for detecting postlung biopsy pneumothorax. In each case, microdose CT resulted in diagnostically sufficient images with effective dose ranges of 0.0417-0.0538 mSv, corresponding to an effective dose range of approximately 2.5 CXRs. In case 3, a small loculated pneumothorax not readily apparent on CXR was more easily appreciated on microdose CT. This case series highlights a novel real-world clinical application of microdose CT for postbiopsy pneumothorax detection which has not been well documented previously that warrants prospective evaluation. Studies are needed to assess microdose CT diagnostic accuracy, feasibility, and clinical impact when used in a postbiopsy procedural setting.

Radiology Case ReportsVol. 21(12)
Western University (CA), University of Guelph (CA)
Good health and well-being
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon